Inspection 345752539 OPENED JAN 28, 2022Closed
Uscg Base Detachment Borinquen 260 Guard Road, Aguadilla, PR 00603 · National Security · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Aguadilla, Puerto Rico · National Security · NAICS 928110
US Coast Guard Base Detachment Borinquen has 2 OSHA inspections on record in Puerto Rico, the first in 2019.
OSHA's last visit started on Jan 28, 2022 after a complaint, in Aguadilla.
Across those inspections OSHA issued 3 citation items: 2 serious and 1 other-than-serious.
OSHA did not attach a penalty to any of these citations.
Most often, OSHA cited 1910.253, gas welding and cutting (2 items).
For context, across all public administration employers the median penalty per cited inspection since 2015 is $0. US Coast Guard Base Detachment Borinquen averages $0 over 1 cited inspection in that time.
Puerto Rico · latest 90 days of OSHA records
109employers cited
Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Puerto Rico
Checking a subcontractor, a client or your own company? Watch US Coast Guard Base Detachment Borinquen and get notified the morning OSHA posts a new citation for it.
Watch this companyUscg Base Detachment Borinquen 260 Guard Road, Aguadilla, PR 00603 · National Security · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Uscg Base Detachment Borinquen 260 Guard Road, Aguadilla, PR 00603 · National Security · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 24, 2020 | Final |
| Citation 1, item 2 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $0 | $0 | Feb 24, 2020 | Final |
| Citation 2, item 1 29 CFR 1910.253(b)(1)(ii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Feb 24, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.253(b)(1)(ii)
(ii) Compressed gas cylinders shall be legibly marked, for the purpose of identifying the gas content, with either the chemical or the trade name of the gas. Such marking shall be by means of stenciling, stamping, or labeling, and shall not be readily removable. Whenever practical, the marking shall be located on the shoulder of the cylinder.
29 CFR 1910.253(b)(4)(iii)
(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.
29 CFR 1910.303(g)(1)
(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.
Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.