OSHA SearchOSHA records by employer

Uss McFaul DDG 74: OSHA inspections and violations

Norfolk, Virginia · National Security · NAICS 928110

1inspections
4citation items
$0current penalties
Mar 17, 2021last inspection

OSHA inspectors have visited Uss McFaul DDG 74 in Virginia one time.

It opened on Mar 17, 2021 as part of a related case, in Norfolk.

In all, OSHA issued 4 citation items: 4 serious.

No penalty came with these citations.

The rule cited most here is 1915.89 (control of hazardous energy (lockout/tags-plus)), 3 times.

Among public administration employers, the typical cited inspection since 2015 ends with a $0 penalty. Uss McFaul DDG 74 averages $0 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Uss McFaul DDG 74: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

246employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Uss McFaul DDG 74 and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345233738 OPENED MAR 17, 2021Closed

Unprogrammed related · Partial · Safety · Federal government · 400 employees at the site · Closed Jan 6, 2022

Onboard Uss Mcfaul (ddg 74) @ Gd Nassco - 200 Ligon St., Norfolk, VA 23523 · National Security · OSHA's record · Phone and website on Google Maps

Incident on Mar 15, 2021 (fatal): Employee is killed after being crushed by engine door

At 8:00 a.m. on March 15, 2021, an employee on board a Navy vessel entered an op en gas turbine engine blow-in door which was tagged out in the open position. Th e door closed on the employee who was crushed and was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1915.89(c)(1) · Control of hazardous energy (lockout/tags-plus)
Serious$0$0Sep 15, 2021Final
Citation 1, item 1b
29 CFR 1915.89(c)(4)(ii) · Control of hazardous energy (lockout/tags-plus)
Serious$0$0Sep 15, 2021Final
Citation 1, item 1c
29 CFR 1915.89(g)(1) · Control of hazardous energy (lockout/tags-plus)
Serious$0$0Sep 15, 2021Final
Citation 1, item 2 Serious$0$0Sep 15, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1915.89 · Control of hazardous energy (lockout/tags-plus)

29 CFR 1915.89(c)(1)

(c) General requirements. (1) The employer shall ensure that, before any authorized employee performs servicing when energization or startup, or the release of hazardous energy, may occur, all energy sources are identified and isolated, and the machinery, equipment, or system is rendered inoperative.

29 CFR 1915.89(c)(4)(ii)

(ii) At least one additional safety measure that, along with the energy-isolating device and tag required in (c)(4)(i) of this section, will provide the equivalent safety available from the use of a lock.

29 CFR 1915.89(g)(1)

(g) Procedures for verification of deenergization and isolation. (1) Before servicing machinery, equipment, or a system that has a lockout/tags-plus system, the employer shall ensure that the authorized employee, or the primary authorized employee in a group lockout/tags-plus application, verifies that the machinery, equipment, or system is deenergized and all energy sources isolated.