OSHA SearchOSHA records by employer

Utah Basement Systems, LLC: OSHA inspections and violations

Logan, Utah · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

3inspections
6citation items
$6,300current penalties
Mar 11, 2019last inspection

Since 2017, OSHA inspectors have visited Utah Basement Systems, LLC in Utah 3 times.

The most recent inspection opened on Mar 11, 2019 to follow up on an earlier case, in West Haven.

In all, OSHA issued 6 citation items: 4 serious and 2 other-than-serious.

The penalties, $6,300 in total, stand where OSHA first set them.

The rule cited most here is 1910.1200 (hazard communication), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Utah Basement Systems, LLC averages $6,300 across 1 cited inspection.

Utah Basement Systems, LLC: OSHA citation items per year, 2017 to 2019
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Utah Basement Systems, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343842274 OPENED MAR 11, 2019Closed

Follow-up · Partial · Health · 5 employees at the site · Closed Mar 13, 2019

3035 Scott Lane, West Haven, UT 84401 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342945359 OPENED FEB 13, 2018Open

Complaint · Partial · Health · 9 employees at the site · Open

49 N Main St. Ste #b, Farmington, UT 84025 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$1,500$1,500May 2, 2018Final
Citation 1, item 1b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0May 2, 2018Final
Citation 1, item 2
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,500$1,500May 2, 2018Final
Citation 1, item 3
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$1,500$1,500May 2, 2018Final
Citation 1, item 4
29 CFR 1926.1203(a) · Confined Spaces in Construction: general requirements
Serious$1,500$1,500May 2, 2018Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$300$300May 2, 2018Final

Inspection 342331311 OPENED MAY 10, 2017Closed

Referral · No inspection · Safety · 7 employees at the site · Closed May 11, 2017

628 N 100 E, Logan, UT 84321 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1926.1203 · Confined Spaces in Construction: general requirements

29 CFR 1926.21 · Construction safety training

29 CFR 1926.95 · Criteria for personal protective equipment

Other plumbing, heating, and air-conditioning contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.