Utah Pacific Bridge & Steel Ltd: OSHA inspections and violations
Lindon, Utah · Fabricated Structural Metal Manufacturing · NAICS 332312
10inspections
33citation items
$2,850current penalties
Mar 21, 2024last inspection
Utah Pacific Bridge & Steel Ltd has 10 OSHA inspections on record in Utah, the first in 1986.
OSHA's last visit started on Mar 21, 2024 after a complaint, in Lindon.
Across those inspections OSHA issued 33 citation items: 11 serious and 22 other-than-serious.
OSHA proposed $5,140 in penalties. After settlements and reviews the total is $2,850, down 45%.
Most often, OSHA cited 1910.180, crawler locomotive and truck cranes (4 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Utah Pacific Bridge & Steel Ltd averages $583 over 3 cited inspections in that time.
1 inspection on this page followed a fatal incident.
Utah Pacific Bridge & Steel Ltd also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Utah · latest 90 days of OSHA records
70employers cited
Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Utah Pacific Bridge & Steel Ltd and get notified the morning OSHA posts a new citation for it.
Incident on Dec 14, 2000 (fatal): Employee killed when stuck by tipped girder
On December 14, 2000, Employee #1 was preparing to weld Nelson studs and shear c onnectors, to a girder. Two other employees were preparing to move a separate la rge girder with two overhead cranes. As they started to lift the girder next to the wall, a plate welded onto the girder being lifted caught the flange of the g irder next to it and caused it to tip over. The tipping girder struck Employee # 1 and killed him.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Lindon site logged 8 recordable injuries or illnesses among about 61 workers: 12.9 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 127 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Utah Pacific bridge & Steel LTD
Lindon · 2025
61
8
6
12.9
3.6
Utah Pacific Bridge & Steel
Lindon · 2021
60
5
2
8.0
3.6
Included with any plan: 3 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.106(d)(4)(iv)
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
29 CFR 1910.106(d)(7)(ia)
(7) Fire control—(i) Extinguishers. Suitable fire control devices, such as small hose or portable fire extinguishers, shall be available at locations where flammable liquids are stored.
Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.