OSHA SearchOSHA records by employer

Valben Construction LLC: OSHA inspections and violations

Davie, Florida · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

1inspections
7citation items
$57,932current penalties
Sep 25, 2024last inspection

OSHA inspectors have visited Valben Construction LLC in Florida one time.

It opened on Sep 25, 2024 as a planned inspection, in Davie and is still open.

In all, OSHA issued 7 citation items: 7 serious.

The penalties, $57,932 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Valben Construction LLC averages $57,932 across 1 cited inspection.

Valben Construction LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Valben Construction LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347778656 OPENED SEP 25, 2024Open

Planned · Partial · Safety · 5 employees at the site · Open

4465 Griffin Rd, Davie, FL 33314 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$8,276$8,276Mar 24, 2025Contested
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$8,276$8,276Mar 24, 2025Contested
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$8,276$8,276Mar 24, 2025Contested
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$8,276$8,276Mar 24, 2025Contested
Citation 1, item 5
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$8,276$8,276Mar 24, 2025Contested
Citation 1, item 6
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$8,276$8,276Mar 24, 2025Contested
Citation 1, item 7
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$8,276$8,276Mar 24, 2025Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other other foundation, structure, and building exterior contractors employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.