OSHA SearchOSHA records by employer

VC Granite Fabrication Inc: OSHA inspections and violations

Lake Park, North Carolina · Cut Stone and Stone Product Manufacturing · NAICS 327991

1inspections
18citation items
$11,100current penalties
Aug 20, 2019last inspection

VC Granite Fabrication Inc has one OSHA inspection on record in North Carolina.

OSHA opened it on Aug 20, 2019 after a complaint, in Lake Park.

From that inspection OSHA issued 18 citation items: 16 serious and 2 other-than-serious.

OSHA proposed $11,100 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.1053, silica dust in general industry (7 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. VC Granite Fabrication Inc averages $11,100 over 1 cited inspection in that time.

VC Granite Fabrication Inc: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

231employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch VC Granite Fabrication Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344267646 OPENED AUG 20, 2019Closed

Complaint · Partial · Health · 3 employees at the site · Closed Nov 10, 2021

13606 East Independence Boulevard, Lake Park, NC 28079 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,100$2,100Dec 11, 2019Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Dec 11, 2019Final
Citation 1, item 1c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Dec 11, 2019Final
Citation 1, item 1d
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Dec 11, 2019Final
Citation 1, item 1e
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Dec 11, 2019Final
Citation 1, item 2
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$600$600Dec 11, 2019Final
Citation 1, item 3a
29 CFR 1910.1053(c) · Silica dust in general industry
Serious$2,100$2,100Dec 11, 2019Final
Citation 1, item 3b
29 CFR 1910.1053(f)(1) · Silica dust in general industry
Serious$0$0Dec 11, 2019Final
Citation 1, item 3c
29 CFR 1910.1053(e)(1) · Silica dust in general industry
Serious$0$0Dec 11, 2019Final
Citation 1, item 3d
29 CFR 1910.1053(f)(2)(i) · Silica dust in general industry
Serious$0$0Dec 11, 2019Final
Citation 1, item 4a
29 CFR 1910.1053(h)(1) · Silica dust in general industry
Serious$2,100$2,100Dec 11, 2019Final
Citation 1, item 4b
29 CFR 1910.1053(h)(2) · Silica dust in general industry
Serious$0$0Dec 11, 2019Final
Citation 1, item 5
29 CFR 1910.1053(i)(1)(i) · Silica dust in general industry
Serious$2,100$2,100Dec 11, 2019Final
Citation 1, item 6a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,100$2,100Dec 11, 2019Final
Citation 1, item 6b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Dec 11, 2019Final
Citation 1, item 6c
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Dec 11, 2019Final
Citation 2, item 1a
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 11, 2019Final
Citation 2, item 1b
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$0$0Dec 11, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(c)

(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of respirable crystalline silica in excess of 50 µg/m 3, calculated as an 8-hour TWA.

29 CFR 1910.1053(e)(1)

(e) Regulated areas—(1) Establishment. The employer shall establish a regulated area wherever an employee's exposure to airborne concentrations of respirable crystalline silica is, or can reasonably be expected to be, in excess of the PEL.

29 CFR 1910.1053(f)(1)

(f) Methods of compliance—(1) Engineering and work practice controls. The employer shall use engineering and work practice controls to reduce and maintain employee exposure to respirable crystalline silica to or below the PEL, unless the employer can demonstrate that such controls are not feasible. Wherever such feasible engineering and work practice controls are not sufficient to reduce employee exposure to or below the PEL, the employer shall nonetheless use them to reduce employee exposure to the lowest feasible level and shall supplement them with the use of respiratory protection that complies with the requirements of paragraph (g) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other cut stone and stone product manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.