OSHA SearchOSHA records by employer

Vector Construction Inc: OSHA inspections and violations

Alberta, Virginia · All Other Specialty Trade Contractors · NAICS 238990

3inspections
14citation items
$14,966current penalties
May 16, 2017last inspection

Vector Construction Inc has 3 OSHA inspections on record in Virginia, the first in 1990.

OSHA's last visit started on May 16, 2017 as part of a related case, in Alberta.

Across those inspections OSHA issued 14 citation items: 5 serious and 9 other-than-serious.

OSHA proposed $18,620 in penalties. After settlements and reviews the total is $14,966, down 20%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. Vector Construction Inc averages $7,308 over 2 cited inspections in that time.

Vector Construction Inc: OSHA citation items per year, 1990 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Vector Construction Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342339272 OPENED MAY 16, 2017Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Aug 7, 2017

Rt. 85 Bridges Structure 2046 Southbound & 2047 Northbound, Alberta, VA 23821 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 16VAC25-60-130
Serious$4,275$3,420Jul 12, 2017Final
Citation 1, item 2
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$2,475$1,980Jul 12, 2017Final
Citation 1, item 3a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Other-than-serious$3,600$2,880Jul 12, 2017Final
Citation 1, item 3b
29 CFR 1926.451(d)(3)(i) · Scaffolds, general requirements
Other-than-serious$0$0Jul 12, 2017Final
Citation 1, item 3c
29 CFR 1926.451(e)(5)(ii) · Scaffolds, general requirements
Other-than-serious$0$0Jul 12, 2017Final
Citation 1, item 3d
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Other-than-serious$0$0Jul 12, 2017Final
Citation 1, item 3e
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Other-than-serious$0$0Jul 12, 2017Final
Citation 1, item 4a
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$4,320$3,456Jul 12, 2017Final
Citation 1, item 4b
29 CFR 1926.502(i)(4) · Fall protection systems
Serious$0$0Jul 12, 2017Final

Inspection 342345709 OPENED MAY 16, 2017Closed

Unprogrammed related · Partial · Health · 5 employees at the site · Closed Aug 7, 2017

Interstate 85,b601,602, Alberta, VA 23821 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$3,600$2,880Jun 27, 2017Final

Inspection 105738447 OPENED APR 9, 1990Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jul 11, 1990

7501 Boulder's View Drive, Richmond, VA 23235 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.500(f)(1) · Scope, application, and definitions applicable to this subpart
Serious$350$350May 15, 1990Closed
Citation 1, item 1b
29 CFR 1926.500(f)(1)(vib) · Scope, application, and definitions applicable to this subpart
Serious$0$0May 15, 1990Closed
Citation 2, item 1
29 CFR 1926.59(f)(5)(i) · Hazard communication
Other-than-serious$0$0May 15, 1990Closed
Citation 2, item 2
29 CFR 1926.59(f)(5)(ii) · Hazard communication
Other-than-serious$0$0May 15, 1990Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(g)(1)(i)(a)

(A) Facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function; or

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.59 · Hazard communication

Other all other specialty trade contractors employers in Virginia

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.