OSHA SearchOSHA records by employer

Versa Integrity Group, Inc.: OSHA inspections and violations

Sumterville, Florida · Testing Laboratories and Services · NAICS 541380

1inspections
2citation items
$14,782current penalties
Jan 17, 2018last inspection

Versa Integrity Group, Inc. has one OSHA inspection on record in Florida.

OSHA opened it on Jan 17, 2018 as a planned inspection, in Sumterville.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $14,782 in penalties and the amount has not been reduced.

For context, across all professional services employers the median penalty per cited inspection since 2015 is $1,820. Versa Integrity Group, Inc. averages $14,782 over 1 cited inspection in that time.

Versa Integrity Group, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Versa Integrity Group, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342882701 OPENED JAN 17, 2018Closed

Planned · Complete · Safety · 15 employees at the site · Closed May 29, 2024

County Road 525 And Us Hwy 301, Sumterville, FL 33585 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Serious$9,239$9,239Jul 10, 2018Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$5,543$5,543Jul 10, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

Other testing laboratories and services employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.