Versatile Fabrication LLC: OSHA inspections and violations

Elkhart, Indiana · Fabricated Structural Metal Manufacturing · NAICS 332312

1inspections
8citation items
$1,650current penalties
Feb 13, 2019last inspection

Versatile Fabrication LLC has one OSHA inspection on record in Indiana.

OSHA opened it on Feb 13, 2019 on a referral, in Elkhart.

From that inspection OSHA issued 8 citation items: 8 serious.

OSHA proposed $3,300 in penalties. After settlements and reviews the total is $1,650, down 50%.

Most often, OSHA cited 1910.217, mechanical power presses (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Versatile Fabrication LLC averages $1,650 over 1 cited inspection in that time.

Versatile Fabrication LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

76employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Versatile Fabrication LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Versatile Fabrication LLC at 4 sites in 2 states. Together they've had 6 inspections and $6,665 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 4 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 343781506 OPENED FEB 13, 2019Closed

Referral · Partial · Safety · 13 employees at the site · Closed Aug 23, 2019

4431 Pine Creek Rd, Elkhart, IN 46516 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.217(b)(7)(v)(a) · Mechanical power presses
Serious$1,500$750Apr 12, 2019Final
Citation 1, item 1b
29 CFR 1910.217(b)(13) · Mechanical power presses
Serious$0$0Apr 12, 2019Final
Citation 1, item 1c
29 CFR 1910.217(b)(14)(i) · Mechanical power presses
Serious$0$0Apr 12, 2019Final
Citation 1, item 1d
29 CFR 1910.217(c)(2)(i)(a) · Mechanical power presses
Serious$0$0Apr 12, 2019Final
Citation 1, item 1e
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$0$0Apr 12, 2019Final
Citation 1, item 1f
29 CFR 1910.217(f)(2) · Mechanical power presses
Serious$0$0Apr 12, 2019Final
Citation 1, item 2
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$1,500$750Apr 12, 2019Final
Citation 1, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$300$150Apr 12, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.217(b)(13)

(13) Control reliability. When required by paragraph (c)(5) of this section, the control system shall be constructed so that a failure within the system does not prevent the normal stopping action from being applied to the press when required, but does prevent initiation of a successive stroke until the failure is corrected. The failure shall be detectable by a simple test, or indicated by the control system. This requirement does not apply to those elements of the control system which have no effect on the protection against point of operation injuries.

29 CFR 1910.217(b)(14)(i)

(i) Be so constructed as to automatically prevent the activation of a successive stroke if the stopping time or braking distance deteriorates to a point where the safety distance being utilized does not meet the requirements set forth in paragraph (c)(3)(iii)(e) or (c)(3)(vii)(c) of this section. The brake monitor used with the Type B gate or movable barrier device shall be installed in a manner to detect slide top-stop overrun beyond the normal limit reasonably established by the employer.

29 CFR 1910.217(b)(7)(v)(a)

(v) Two-hand controls for single stroke shall conform to the following requirements:

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements