OSHA SearchOSHA records by employer

Victor Aguilar: OSHA inspections and violations

Edmond, Oklahoma · Masonry Contractors · NAICS 238140

1inspections
3citation items
$5,200current penalties
Mar 16, 2015last inspection

OSHA inspectors have visited Victor Aguilar in Oklahoma one time.

It opened on Mar 16, 2015 as a planned inspection, in Edmond.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $5,200 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Victor Aguilar averages $5,200 across 1 cited inspection.

Victor Aguilar: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

53employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Victor Aguilar and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340471044 OPENED MAR 16, 2015Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 30, 2018

4706 Spectacular Bid Ave., Edmond, OK 73003 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,600$1,600Jul 8, 2015Final
Citation 1, item 2
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$1,600$1,600Jul 8, 2015Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,000$2,000Jul 8, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

Other masonry contractors employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.