OSHA SearchOSHA records by employer

Victor Lopez: OSHA inspections and violations

Oklahoma City, Oklahoma · Masonry Contractors · NAICS 238140

2inspections
7citation items
$11,758current penalties
Sep 6, 2016last inspection

OSHA has inspected Victor Lopez 2 times in Oklahoma since 2016.

The latest one began on Sep 6, 2016 as a planned inspection, in Oklahoma City.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $11,758 and still stand at $11,758.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Victor Lopez averages $5,879 (2 cited inspections).

Victor Lopez: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

52employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Victor Lopez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341766558 OPENED SEP 6, 2016Closed

Planned · Partial · Safety · 5 employees at the site · Closed May 17, 2022

6200 W. Memorial Rd., Oklahoma City, OK 73142 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,138$2,138Nov 28, 2016Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Nov 28, 2016Final

Inspection 341675882 OPENED AUG 3, 2016Closed

Planned · Partial · Safety · 3 employees at the site · Closed Dec 9, 2019

6000 W Memorial Rd, Oklahoma City, OK 73142 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,138$2,138Sep 20, 2016Final
Citation 1, item 2
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$2,138$2,138Sep 20, 2016Final
Citation 1, item 3a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,672$2,672Sep 20, 2016Final
Citation 1, item 3b
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$0$0Sep 20, 2016Final
Citation 1, item 4
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$2,672$2,672Sep 20, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(e)(9)(iv)

(iv) Cross braces on tubular welded frame scaffolds shall not be used as a means of access or egress.