Victoria Munoz Masonry: OSHA inspections and violations

Flower Mound, Texas · Masonry Contractors · NAICS 238140

1inspections
4citation items
$6,125current penalties
Mar 20, 2018last inspection

Victoria Munoz Masonry has one OSHA inspection on record in Texas.

OSHA opened it on Mar 20, 2018 as a planned inspection, in Flower Mound.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $6,125 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Victoria Munoz Masonry averages $6,125 over 1 cited inspection in that time.

Victoria Munoz Masonry: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

14 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Victoria Munoz Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343033627 OPENED MAR 20, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 6, 2018

2209 Pinnacle Ln, Flower Mound, TX 75028 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,356$2,356Apr 6, 2018Final
Citation 1, item 1b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Apr 6, 2018Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,413$1,413Apr 6, 2018Final
Citation 1, item 3
29 CFR 1926.451(h)(2)(iii) · Scaffolds, general requirements
Serious$2,356$2,356Apr 6, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.