OSHA SearchOSHA records by employer

Vigor Alaska Seward, LLC: OSHA inspections and violations

Seward, Alaska · Ship Building and Repairing · NAICS 336611

6inspections
15citation items
$16,065current penalties
Apr 4, 2016last inspection

Since 2016, OSHA inspectors have visited Vigor Alaska Seward, LLC in Alaska 6 times.

The most recent inspection opened on Apr 4, 2016 as a planned inspection, in Seward.

In all, OSHA issued 15 citation items: 14 serious and 1 other-than-serious.

The proposed penalties came to $22,950; today they stand at $16,065, 30% less.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Vigor Alaska Seward, LLC averages $5,355 across 3 cited inspections.

Vigor Alaska Seward, LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Alaska · latest 90 days of OSHA records

37employers cited

Get notified the morning OSHA posts each new citation in Alaska: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alaska

Checking a subcontractor, a client or your own company? Watch Vigor Alaska Seward, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341382059 OPENED APR 4, 2016Closed

Planned · Complete · Safety · 40 employees at the site · Closed Jun 13, 2016

Mile 7 Nash Road, Seward, AK 99664 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.242(b) · Hand and power tools
Serious$2,550$1,785May 10, 2016Final
Citation 1, item 2a
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$2,550$1,785May 10, 2016Final
Citation 1, item 2b
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$0$0May 10, 2016Final
Citation 1, item 2c
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0May 10, 2016Final
Citation 1, item 3
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$2,550$1,785May 10, 2016Final
Citation 1, item 4a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$2,550$1,785May 10, 2016Final
Citation 1, item 4b
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$0$0May 10, 2016Final
Citation 1, item 4c
29 CFR 1910.305(j)(2)(vi) · Electrical wiring methods
Serious$0$0May 10, 2016Final
Citation 1, item 5
29 CFR 1915.89(b) · Control of hazardous energy (lockout/tags-plus)
Serious$3,400$2,380May 10, 2016Final
Citation 1, item 6
29 CFR 1915.134(b) · Abrasive wheels
Serious$2,550$1,785May 10, 2016Final

Inspection 341384592 OPENED APR 4, 2016Closed

Planned · Complete · Health · 40 employees at the site · Closed Jul 20, 2016

Mile 7 Nash Road, Seward, AK 99664 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$3,400$2,380May 10, 2016Final
Citation 1, item 1b
29 CFR 1910.219(c)(3) · Belts, pulleys and power-transmission parts
Serious$0$0May 10, 2016Final
Citation 1, item 1c
29 CFR 1910.213(i)(1) · Woodworking machinery
Serious$0$0May 10, 2016Final
Citation 2, item 1
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0May 10, 2016Final

Inspection 341384717 OPENED APR 4, 2016Closed

Planned · Complete · Safety · 40 employees at the site · Closed Jun 13, 2016

Uscg Mustang Mile 7 Nash Road, Seward, AK 99664 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1915.71(d)(4) · Scaffolds or staging
Serious$3,400$2,380May 10, 2016Final

Inspection 341384808 OPENED APR 4, 2016Closed

Planned · Complete · Health · 40 employees at the site · Closed May 10, 2016

Uscg Mustang Mile 7 Nash Road, Seward, AK 99664 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341384915 OPENED APR 4, 2016Closed

Planned · Complete · Safety · 40 employees at the site · Closed May 10, 2016

Valdez Star Mile 7 Nash Road, Seward, AK 99664 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341384956 OPENED APR 4, 2016Closed

Planned · Complete · Health · 40 employees at the site · Closed May 10, 2016

Valdez Star Mile 7 Nash Road, Seward, AK 99664 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(i)(1)

(i) Bandsaws and band resaws. (1) All portions of the saw blade shall be enclosed or guarded, except for the working portion of the blade between the bottom of the guide rolls and the table. Bandsaw wheels shall be fully encased. The outside periphery of the enclosure shall be solid. The front and back of the band wheels shall be either enclosed by solid material or by wire mesh or perforated metal. Such mesh or perforated metal shall be not less than 0.037 inch (U.S. Gage No. 20), and the openings shall be not greater than three-eighths inch. Solid material used for this purpose shall be of an equivalent strength and firmness. The guard for the portion of the blade between the sliding guide and the upper-saw-wheel guard shall protect the saw blade at the front and outer side. This portion of the guard shall be self-adjusting to raise and lower with the guide. The upper-wheel guard shall

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(c)(2)(i)

(2) Guarding horizontal shafting. (i) All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.

29 CFR 1910.219(c)(3)

(3) Guarding vertical and inclined shafting. Vertical and inclined shafting seven (7) feet or less from floor or working platform, excepting maintenance runways, shall be enclosed with a stationary casing in accordance with requirements of paragraphs (m) and (o) of this section.

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1915.134 · Abrasive wheels

29 CFR 1915.71 · Scaffolds or staging

29 CFR 1915.89 · Control of hazardous energy (lockout/tags-plus)

Other ship building and repairing employers in Alaska

Alert subscribers get notified of each newly cited employer in Alaska the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.