2inspections
11citation items
$0current penalties
Jul 8, 2015last inspection

Village of Cahokia- Code Enforcement has 2 OSHA inspections on record in Illinois, the first in 2015.

OSHA's last visit started on Jul 8, 2015 as a planned inspection, in Cahokia.

Across those inspections OSHA issued 11 citation items: 10 serious and 1 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.305, electrical wiring methods (4 items).

For context, across all public administration employers the median penalty per cited inspection since 2015 is $0. Village of Cahokia- Code Enforcement averages $0 over 2 cited inspections in that time.

Village of Cahokia- Code Enforcement: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

416employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Village of Cahokia- Code Enforcement and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340685791 OPENED JUL 8, 2015Closed

Planned · Partial · Health · Local government · 2 employees at the site · Closed Feb 23, 2016

201 West 4th, Cahokia, IL 62206 · Other General Government Support · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1001(j)(3)(i) · Asbestos in general industry
Serious$0$0Sep 9, 2015Final

Inspection 340659358 OPENED MAY 27, 2015Closed

Planned · Complete · Safety · Local government · 5 employees at the site · Closed Oct 15, 2015

201 West 4th, Cahokia, IL 62206 · Regulation, Licensing, and Inspection of Miscellaneous Commercial Sectors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(b)(1) · General requirements
Serious$0$0Aug 21, 2015Final
Citation 1, item 2
29 CFR 1910.303(b)(7)(iii) · Electrical equipment, general requirements
Serious$0$0Aug 21, 2015Final
Citation 1, item 3a
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$0$0Aug 21, 2015Final
Citation 1, item 3b
29 CFR 1910.305(c)(4) · Electrical wiring methods
Serious$0$0Aug 21, 2015Final
Citation 1, item 4
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Aug 21, 2015Final
Citation 1, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Aug 21, 2015Final
Citation 1, item 6
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Aug 21, 2015Final
Citation 1, item 7a
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Aug 21, 2015Final
Citation 1, item 7b
29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods
Serious$0$0Aug 21, 2015Final
Citation 2, item 1
29 CFR 56 IL ADMIN CODE PART 350.260(A)
Other-than-serious$0$0Aug 21, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1001 · Asbestos in general industry

29 CFR 1910.1001(j)(3)(i)

(3) Duties of employers and building and facility owners. (i) Building and facility owners shall determine the presence, location, and quantity of ACM and/or PACM at the work site. Employers and building and facility owners shall exercise due diligence in complying with these requirements to inform employers and employees about the presence and location of ACM and PACM.

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(iii)

(iii) Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, may not be damaged or contaminated by foreign materials such as paint, plaster, cleaners, abrasives, or corrosive residues.

29 CFR 1910.303(b)(7)(iv)

(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.

29 CFR 1910.305 · Electrical wiring methods

Other regulation, licensing, and inspection of miscellaneous commercial sectors employers in Illinois