3inspections
5citation items
$7,953current penalties
Sep 9, 2024last inspection

Vip Construction Inc. has 3 OSHA inspections on record in Pennsylvania, the first in 2008.

OSHA's last visit started on Sep 9, 2024 on a referral, in Blue Bell.

Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $9,854 in penalties. After settlements and reviews the total is $7,953, down 19%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Vip Construction Inc. averages $6,828 over 1 cited inspection in that time.

Vip Construction Inc.: OSHA citation items per year, 2008 to 2024
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Vip Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347740607 OPENED SEP 9, 2024Closed

Referral · Partial · Safety · 4 employees at the site · Closed Mar 14, 2025

889 Dekalb Pike, Blue Bell, PA 19422 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Other-than-serious$9,104$6,828Feb 26, 2025Final

Inspection 347735748 OPENED SEP 5, 2024Closed

Complaint · Partial · Health · 3 employees at the site · Closed Feb 13, 2025

889 Dekalb Pike, Blue Bell, PA 19422 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311273916 OPENED OCT 23, 2008Closed

Referral · Partial · Safety · 11 employees at the site · Closed Jun 16, 2009

The Court At Upper Providence Bldg. H, Royersford, PA 19465 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$750$1,125Dec 11, 2008Closed
Citation 2, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Dec 11, 2008Closed
Citation 2, item 1c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Dec 11, 2008Closed
Citation 2, item 1d
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$0Dec 11, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.453 · Aerial lifts

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.