Sheboygan, Wisconsin · Other Plastics Product Manufacturing · NAICS 326192
3inspections
4citation items
$5,355current penalties
Oct 19, 2015last inspection
OSHA has inspected Vpi Corporation 3 times in Wisconsin since 2002.
The latest one began on Oct 19, 2015 on a referral, in Sheboygan.
Those inspections ended with 4 citation items: 2 serious and 2 other-than-serious.
Penalties were first proposed at $5,355 and still stand at $5,355.
Machine guarding comes up most often in these citations: 2 items under 1910.212.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Vpi Corporation averages $5,355 (1 cited inspection).
Vpi Corporation also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Wisconsin · latest 90 days of OSHA records
223employers cited
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2022, the Sheboygan site logged 2 recordable injuries or illnesses among about 87 workers: 2.4 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 29 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
VPI Sheboygan
Sheboygan · 2022
87
2
1
2.4
2.6
Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
An employee was cleaning out a knife gate. The equipment was turned off. While using an airline and nozzle to blow out material the airline hit the on/off switch and the gate was activated. The employee's thumb was crushed under the gate and amputated by the machine.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
29 CFR 1910.147(c)(6)(ii)
(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.
Other other plastics product manufacturing employers in Wisconsin
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.