Inspection 349026419 OPENED JUN 30, 2026Closed
149 Sunset Blvd., Washington, PA 15301 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pittsburgh, Pennsylvania · Water and Sewer Line and Related Structures Construction · NAICS 237110
W a Petrakis Contracting LLC has 7 OSHA inspections on record in Pennsylvania, the first in 2003.
OSHA's last visit started on Jun 30, 2026 as a planned inspection, in Washington.
Across those inspections OSHA issued 8 citation items: 5 serious and 3 other-than-serious.
OSHA proposed $7,561 in penalties and the amount has not been reduced.
Most often, OSHA cited 1926.652, trench protection (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. W a Petrakis Contracting LLC averages $3,500 over 2 cited inspections in that time.
Pennsylvania · latest 90 days of OSHA records
280employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch W a Petrakis Contracting LLC and get notified the morning OSHA posts a new citation for it.
Watch this company149 Sunset Blvd., Washington, PA 15301 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
West Beau Street, Washington, PA 15301 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1b 29 CFR 1926.651(i)(3) · Excavations |
Other-than-serious | $0 | $3,700 | Jun 13, 2024 | Final |
| Citation 1, item 1c 29 CFR 1926.1053(b)(16) · Ladders in construction |
Other-than-serious | $0 | $0 | Jun 13, 2024 | Final |
69 Franfort Ave Tomoka Avenue Corner Intersection, Pittsburgh, PA 15222 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
701 Drey Street, Arnold, PA 15068 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.652(g)(2) · Trench protection |
Serious | $5,461 | $3,300 | Oct 20, 2021 | Final |
| Citation 1, item 1b 29 CFR 1926.652(b)(2) · Trench protection |
Serious | $0 | $0 | Oct 20, 2021 | Final |
| Citation 2, item 1 29 CFR 1926.1053(b)(1) · Ladders in construction |
Other-than-serious | $0 | $0 | Oct 20, 2021 | Final |
Route 220 North, Bedford, PA 15522 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
63 Mount Oliver Street, Pittsburgh, PA 15210 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Route 19, Upper St Clair, PA 15241 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(c)(2) · Excavations |
Serious | $300 | $200 | Sep 25, 2003 | Closed |
| Citation 1, item 2 29 CFR 1926.651(k)(2) · Excavations |
Serious | $300 | $165 | Sep 25, 2003 | Closed |
| Citation 1, item 3 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $1,500 | $1,000 | Sep 25, 2003 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.1053(b)(16)
(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.
29 CFR 1926.651(c)(2)
(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.