OSHA SearchOSHA records by employer

W&K Siding LLC: OSHA inspections and violations

Toano, Virginia · Siding Contractors · NAICS 238170

1inspections
6citation items
$2,685current penalties
Oct 25, 2024last inspection

OSHA inspectors have visited W&K Siding LLC in Virginia one time.

It opened on Oct 25, 2024, in Toano and is still open.

In all, OSHA issued 6 citation items: 6 serious.

The penalties, $2,685 in total, stand where OSHA first set them.

The rule cited most here is 1926.1053 (ladders in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. W&K Siding LLC averages $2,685 across 1 cited inspection.

W&K Siding LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch W&K Siding LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347843781 OPENED OCT 25, 2024Open

Unprogrammed other · Partial · Safety · 11 employees at the site · Open

9076 Imagination Drive, Toano, VA 23168 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,685$2,685Apr 20, 2025Final
Citation 1, item 1b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Apr 20, 2025Final
Citation 1, item 1c
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0Apr 20, 2025Final
Citation 1, item 1d
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$0$0Apr 20, 2025Final
Citation 1, item 1e
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$0$0Apr 20, 2025Final
Citation 1, item 1f
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Apr 20, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(5)(i)

(5)(i) Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other siding contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.