OSHA SearchOSHA records by employer

W D Masonry, LLC: OSHA inspections and violations

Tampa, Florida · Masonry Contractors · NAICS 238140

4inspections
11citation items
$14,734current penalties
Apr 13, 2017last inspection

OSHA has inspected W D Masonry, LLC 4 times in Florida since 2003.

The latest one began on Apr 13, 2017, in Gainesville.

Those inspections ended with 11 citation items: 9 serious and 2 other-than-serious.

Penalties were first proposed at $17,234 and now stand at $14,734, 15% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 8 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and W D Masonry, LLC averages $9,234 (1 cited inspection).

W D Masonry, LLC: OSHA citation items per year, 2003 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch W D Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342258209 OPENED APR 13, 2017Closed

Unprogrammed other · Complete · Safety · 13 employees at the site · Closed Feb 22, 2018

3490 Sw Archer Road, Gainesville, FL 32608 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$3,078$3,078May 25, 2017Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,078$3,078May 25, 2017Final
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$3,078$3,078May 25, 2017Final

Inspection 309323467 OPENED AUG 19, 2005Closed

Planned · Partial · Safety · 20 employees at the site · Closed Sep 19, 2005

1450 John Lake Road, Clermont, FL 34711 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$2,000$1,000Aug 31, 2005Closed

Inspection 308056647 OPENED AUG 11, 2004Closed

Planned · Complete · Safety · 20 employees at the site · Closed May 24, 2005

7921 Gall Blvd., Zephryhills, FL 33541 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$900$675Nov 2, 2004Closed
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$900$675Nov 2, 2004Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,575$1,181Nov 2, 2004Closed
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,125$844Nov 2, 2004Closed
Citation 2, item 1
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Other-than-serious$0$0Nov 2, 2004Closed

Inspection 306769829 OPENED JUN 26, 2003Closed

Unprogrammed other · Partial · Safety · 12 employees at the site · Closed Mar 9, 2005

Lowe's Project / 4010 S. Dale Mabry, Tampa, FL 33611 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$1,500$1,125Jul 11, 2003Closed
Citation 2, item 1
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Other-than-serious$0$0Jul 11, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(4)

(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater.

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)(iv)

(iv) Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.