OSHA SearchOSHA records by employer

W513 Management LLC: OSHA inspections and violations

Brooklyn, New York · Framing Contractors · NAICS 238130

1inspections
5citation items
$9,000current penalties
Oct 25, 2023last inspection

W513 Management LLC has one OSHA inspection on record in New York.

OSHA opened it on Oct 25, 2023 as a planned inspection, in Brooklyn.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $13,828 in penalties. After settlements and reviews the total is $9,000, down 35%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. W513 Management LLC averages $9,000 over 1 cited inspection in that time.

W513 Management LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

18 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch W513 Management LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347057945 OPENED OCT 25, 2023Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 15, 2026

1736 80th Street, Brooklyn, NY 11214 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,457$2,250Apr 22, 2024Final
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Apr 22, 2024Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(iii) · Scaffolds, general requirements
Serious$3,457$2,250Apr 22, 2024Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,457$2,250Apr 22, 2024Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,457$2,250Apr 22, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(c)(1)(iii)

(iii) Ties, guys, braces, or outriggers shall be used to prevent the tipping of supported scaffolds in all circumstances where an eccentric load, such as a cantilevered work platform, is applied or is transmitted to the scaffold.