Inspection 349190801 OPENED SEP 29, 2026Open
655 Fairview Road, Wytheville, VA 24382 · Railroad Rolling Stock Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Wytheville, Virginia · Railroad Rolling Stock Manufacturing · NAICS 336510
Wabtec Components LLC has 4 OSHA inspections on record in Virginia, the first in 2024.
OSHA's last visit started on Sep 29, 2026 as a planned inspection, in Wytheville, and the case has not closed yet.
Across those inspections OSHA issued 3 citation items: 3 serious.
OSHA proposed $8,445 in penalties. After settlements and reviews the total is $5,912, down 30%.
Most often, OSHA cited 1910.305, electrical wiring methods (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Wabtec Components LLC averages $5,912 over 1 cited inspection in that time.
Want to know if OSHA cites Wabtec Components LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company655 Fairview Road, Wytheville, VA 24382 · Railroad Rolling Stock Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
655 Fairview Road, Wytheville, VA 24382 · Railroad Rolling Stock Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
655 Fairview Road, Wytheville, VA 24382 · Railroad Rolling Stock Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
365 George James Drive, Wytheville, VA 24382 · Railroad Rolling Stock Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.305(a)(2)(x) · Electrical wiring methods |
Serious | $8,445 | $5,912 | Oct 25, 2024 | Final |
| Citation 1, item 1b 29 CFR 1910.305(a)(2)(xi) · Electrical wiring methods |
Serious | $0 | $0 | Oct 25, 2024 | Final |
| Citation 1, item 1c 29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods |
Serious | $0 | $0 | Oct 25, 2024 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.305(a)(2)(x)
(x) Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.
29 CFR 1910.305(a)(2)(xi)
(xi) Cable assemblies and flexible cords and cables shall be supported in place at intervals that ensure that they will be protected from physical damage. Support shall be in the form of staples, cables ties, straps, or similar type fittings installed so as not to cause damage.
29 CFR 1910.305(g)(1)(iv)(b)
(B) Where run through holes in walls, ceilings, or floors;
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.