OSHA SearchOSHA records by employer

Wall-Tech, LLC: OSHA inspections and violations

Mount Juliet, Tennessee · Drywall and Insulation Contractors · NAICS 238310

5inspections
14citation items
$10,800current penalties
Jul 8, 2020last inspection

OSHA has inspected Wall-Tech, LLC 5 times in Tennessee since 2004.

The latest one began on Jul 8, 2020 as a planned inspection, in Nashville; the case is still open.

Those inspections ended with 14 citation items: 12 serious and 2 other-than-serious.

Penalties were first proposed at $10,800 and still stand at $10,800.

Scaffolds, general requirements comes up most often in these citations: 8 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Wall-Tech, LLC averages $4,400 (1 cited inspection).

Wall-Tech, LLC: OSHA citation items per year, 2004 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Wall-Tech, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344827332 OPENED JUL 8, 2020Open

Planned · Complete · Safety · 4 employees at the site · Open

6801 Charlotte Pike, Nashville, TN 37205 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$4,000$4,000Jul 29, 2020Final
Citation 2, item 1
29 CFR TDLWD RULE 800-01-04-.23(4)(A)
Other-than-serious$400$400Oct 8, 2020Final

Inspection 316031657 OPENED SEP 14, 2011Closed

Planned · Complete · Safety · 8 employees at the site · Closed Nov 2, 2011

50 Northcrest Dr, Springfield, TN 37172 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$800$800Oct 11, 2011Closed

Inspection 312236045 OPENED MAY 21, 2008Closed

Planned · Complete · Safety · 61 employees at the site · Closed Aug 6, 2008

140 Mir Parkway, Hendersonville, TN 37075 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$800$800Jul 25, 2008Closed
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jul 25, 2008Closed
Citation 1, item 1c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Jul 25, 2008Closed
Citation 1, item 1d
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$0$0Jul 25, 2008Closed

Inspection 308709310 OPENED APR 20, 2005Closed

Planned · Complete · Safety · 3 employees at the site · Closed Sep 7, 2005

1177 Old Hickory Blvd, Brentwood, TN 37027 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0May 18, 2005Closed

Inspection 307675355 OPENED MAY 6, 2004Closed

Planned · Complete · Safety · 8 employees at the site · Closed Sep 23, 2004

1777 Tate Lane, Mount Juliet, TN 37122 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$900$900Aug 9, 2004Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$900$900Aug 9, 2004Closed
Citation 1, item 3
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Serious$900$900Aug 9, 2004Closed
Citation 1, item 4a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,050$1,050Aug 9, 2004Closed
Citation 1, item 4b
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$0$0Aug 9, 2004Closed
Citation 1, item 5
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,050$1,050Aug 9, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction