Inspection 346733181 OPENED MAY 24, 2023Closed
3900 Motors Industrial Way, Chamblee, GA 30366 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Peachtree City, Georgia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
Since 2006, OSHA inspectors have visited Wallace Electric Company in Georgia 6 times.
The most recent inspection opened on May 24, 2023, in Chamblee.
In all, OSHA issued 4 citation items: 4 serious.
The proposed penalties came to $10,049; today they stand at $7,979, 21% less.
The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Wallace Electric Company averages $3,104 across 1 cited inspection.
Georgia · latest 90 days of OSHA records
147employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Georgia
Checking a subcontractor, a client or your own company? Watch Wallace Electric Company and get notified the morning OSHA posts a new citation for it.
Watch this company3900 Motors Industrial Way, Chamblee, GA 30366 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
900 Athena Dr, Athens, GA 30605 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1075 Frank C Amerson Jr. Parkway, Macon, GA 31216 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $5,174 | $3,104 | Oct 18, 2018 | Final |
1801 Rockdale Industrial Blvd., Conyers, GA 30012 · Other Lighting Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $2,975 | $2,975 | Nov 9, 2011 | Closed |
2081 Eatonton Hwy, Madison, GA 30650 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $900 | $900 | Apr 20, 2007 | Closed |
201 Kelly Dr., Peachtree City, GA 30269 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.454(a) · Scaffold training |
Serious | $1,000 | $1,000 | Jan 4, 2007 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(g)(2)(i)
(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
29 CFR 1926.404(b)(1)(ii)
(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.
Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.