OSHA SearchOSHA records by employer

Wallace Electric Company: OSHA inspections and violations

Peachtree City, Georgia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

6inspections
4citation items
$7,979current penalties
May 24, 2023last inspection

Since 2006, OSHA inspectors have visited Wallace Electric Company in Georgia 6 times.

The most recent inspection opened on May 24, 2023, in Chamblee.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $10,049; today they stand at $7,979, 21% less.

The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Wallace Electric Company averages $3,104 across 1 cited inspection.

Wallace Electric Company: OSHA citation items per year, 2006 to 2023
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

147employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Wallace Electric Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346733181 OPENED MAY 24, 2023Closed

Unprogrammed other · Partial · Safety · 1 employee at the site · Closed Jun 15, 2023

3900 Motors Industrial Way, Chamblee, GA 30366 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346242852 OPENED SEP 21, 2022Closed

Planned · Complete · Safety · 10 employees at the site · Closed Dec 20, 2022

900 Athena Dr, Athens, GA 30605 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343444469 OPENED SEP 6, 2018Closed

Unprogrammed other · Complete · Safety · 12 employees at the site · Closed Nov 9, 2018

1075 Frank C Amerson Jr. Parkway, Macon, GA 31216 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$5,174$3,104Oct 18, 2018Final

Inspection 315738773 OPENED SEP 21, 2011Closed

Unprogrammed related · Partial · Safety · 10 employees at the site · Closed Nov 30, 2011

1801 Rockdale Industrial Blvd., Conyers, GA 30012 · Other Lighting Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$2,975$2,975Nov 9, 2011Closed

Inspection 311032304 OPENED MAR 27, 2007Closed

Unprogrammed other · Complete · Safety · 35 employees at the site · Closed May 16, 2007

2081 Eatonton Hwy, Madison, GA 30650 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$900$900Apr 20, 2007Closed

Inspection 309259414 OPENED DEC 4, 2006Closed

Planned · Complete · Safety · 2 employees at the site · Closed Mar 21, 2007

201 Kelly Dr., Peachtree City, GA 30269 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.454(a) · Scaffold training
Serious$1,000$1,000Jan 4, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.454 · Scaffold training

Other electrical contractors and other wiring installation contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.