OSHA SearchOSHA records by employer

Wambli Ska: OSHA inspections and violations

Rapid City, South Dakota · Meat Processed from Carcasses · NAICS 311612

1inspections
3citation items
$1,519current penalties
Dec 10, 2025last inspection

OSHA has inspected Wambli Ska once in South Dakota.

The inspection began on Dec 10, 2025 as a planned inspection, in Rapid City.

That inspection ended with 3 citation items: 1 serious and 2 other-than-serious.

Penalties were first proposed at $2,532 and now stand at $1,519, 40% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 2 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,872, and Wambli Ska averages $1,519 (1 cited inspection).

Wambli Ska: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Wambli Ska again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348634940 OPENED DEC 10, 2025Closed

Planned · Partial · Safety · 11 employees at the site · Closed Mar 13, 2026

1585 Valley Drive, Rapid City, SD 57703 · Meat Processed from Carcasses · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,532$1,519Feb 4, 2026Final
Citation 2, item 1a
29 CFR 1910.147(d)(2) · Lockout/tagout
Other-than-serious$0$0Feb 4, 2026Final
Citation 2, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Feb 4, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(d)(2)

(2) Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other meat processed from carcasses employers in South Dakota