OSHA SearchOSHA records by employer

Wang X Group LLC: OSHA inspections and violations

Washington, District of Columbia · Residential Remodelers · NAICS 236118

1inspections
6citation items
$7,521current penalties
Feb 10, 2022last inspection

OSHA has inspected Wang X Group LLC once in District of Columbia.

The inspection began on Feb 10, 2022 as a planned inspection, in Washington; the case is still open.

That inspection ended with 6 citation items: 4 serious and 2 other-than-serious.

Penalties were first proposed at $7,521 and still stand at $7,521.

Ladders in construction comes up most often in these citations: 2 items under 1926.1053.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Wang X Group LLC averages $7,521 (1 cited inspection).

Wang X Group LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Wang X Group LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345784540 OPENED FEB 10, 2022Open

Planned · Complete · Safety · 4 employees at the site · Open

1509 D Street Ne, Washington, DC 20002 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$1,585$1,585Aug 9, 2022Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,351$4,351Aug 9, 2022Final
Citation 1, item 3a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,585$1,585Aug 9, 2022Final
Citation 1, item 3b
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$0$0Aug 9, 2022Final
Citation 2, item 1
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Other-than-serious$0$0Aug 9, 2022Final
Citation 2, item 2
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Aug 9, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other residential remodelers employers in District of Columbia

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.