OSHA SearchOSHA records by employer

Wasatch Siding & Rain Gutter Inc.: OSHA inspections and violations

Tooele, Utah · Siding Contractors · NAICS 238170

6inspections
19citation items
$6,465current penalties
May 31, 2023last inspection

Wasatch Siding & Rain Gutter Inc. has 6 OSHA inspections on record in Utah, the first in 2009.

OSHA's last visit started on May 31, 2023 after a complaint, in Bountiful.

Across those inspections OSHA issued 19 citation items: 16 serious and 3 other-than-serious.

OSHA proposed $17,200 in penalties. After settlements and reviews the total is $6,465, down 62%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Wasatch Siding & Rain Gutter Inc. averages $1,620 over 2 cited inspections in that time.

Wasatch Siding & Rain Gutter Inc.: OSHA citation items per year, 2009 to 2023
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Wasatch Siding & Rain Gutter Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346736788 OPENED MAY 31, 2023Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Sep 14, 2023

1800 S & Main Street, Bountiful, UT 84010 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$3,500$1,740Jun 30, 2023Final
Citation 1, item 1b
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$0Jun 30, 2023Final

Inspection 344088125 OPENED JUN 13, 2019Closed

Planned · Partial · Safety · 9 employees at the site · Closed Aug 19, 2019

535 E Millcreek Way, Salt Lake City, UT 84106 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,500$750Jun 27, 2019Final
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$750Jun 27, 2019Final
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jun 27, 2019Final
Citation 1, item 2c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jun 27, 2019Final
Citation 1, item 2d
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Jun 27, 2019Final

Inspection 315876409 OPENED JAN 19, 2012Closed

Referral · Partial · Safety · 9 employees at the site · Closed Apr 17, 2013

4414 S Wynridge Ln, West Valley City, UT 84128 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$2,000$1,000Jun 15, 2012Closed
Citation 1, item 1b
29 CFR 1926.1053(b)(7) · Ladders in construction
Serious$0$0Jun 15, 2012Closed
Citation 1, item 1c
29 CFR 1926.1053(b)(15) · Ladders in construction
Serious$0$0Jun 15, 2012Closed
Citation 1, item 1d
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Jun 15, 2012Closed
Citation 1, item 1e
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0Jun 15, 2012Closed

Inspection 315873190 OPENED SEP 21, 2011Closed

Planned · Partial · Safety · 10 employees at the site · Closed Apr 17, 2013

8200 S 7400 W, West Jordan, UT 84084 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,050$1,050Oct 18, 2011Closed

Inspection 314194085 OPENED MAR 31, 2011Closed

Referral · Partial · Safety · 6 employees at the site · Closed Apr 30, 2012

1195 N 1100 E, American Fork, UT 84003 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,000$250Jun 8, 2011Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$2,000$0Jun 8, 2011Closed

Inspection 312410905 OPENED JUL 15, 2009Closed

Accident · Partial · Safety · 7 employees at the site · Closed Dec 2, 2009

650 E 1480 N, Tooele, UT 84074 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$380Sep 16, 2009Closed
Citation 1, item 2
29 CFR 1926.454(a) · Scaffold training
Serious$1,500$380Sep 16, 2009Closed
Citation 2, item 1
29 CFR 10005 C01
Other-than-serious$500$127Sep 16, 2009Closed
Citation 2, item 2
29 CFR 10005 C02
Other-than-serious$150$38Sep 16, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(15)

(15) Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other siding contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.