OSHA SearchOSHA records by employer

Washingtonville Vill DPW: OSHA inspections and violations

Washingtonville, New York · Highway, Street, and Bridge Construction · NAICS 237310

6inspections
36citation items
$0current penalties
Feb 19, 2016last inspection

Washingtonville Vill DPW has 6 OSHA inspections on record in New York, the first in 2008.

OSHA's last visit started on Feb 19, 2016 to follow up on an earlier case, in Washingtonville.

Across those inspections OSHA issued 36 citation items: 24 serious and 12 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.304, grounding and circuit protection (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Washingtonville Vill DPW averages $0 over 1 cited inspection in that time.

Washingtonville Vill DPW: OSHA citation items per year, 2008 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

22 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Washingtonville Vill DPW and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341286862 OPENED FEB 19, 2016Closed

Follow-up · Partial · Safety · Local government · 6 employees at the site · Closed Feb 19, 2016

1 Walt Cole Boulevard, Washingtonville, NY 10992 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341024271 OPENED OCT 29, 2015Closed

Planned · Complete · Health · Local government · 6 employees at the site · Closed Feb 24, 2016

1 Walt Cole Boulevard, Washingtonville, NY 10992 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340832443 OPENED AUG 4, 2015Closed

Planned · Complete · Safety · Local government · 6 employees at the site · Closed Dec 8, 2016

1 Walt Cole Boulevard, Washingtonville, NY 10992 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.120(q)(1) · Hazardous waste operations and emergency response
Serious$0$0Dec 16, 2015Final
Citation 1, item 2
29 CFR 1910.120(q)(6) · Hazardous waste operations and emergency response
Serious$0$0Dec 16, 2015Final
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$0$0Dec 16, 2015Final
Citation 1, item 4
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Dec 16, 2015Final
Citation 1, item 5
29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements
Serious$0$0Dec 16, 2015Final
Citation 1, item 6
29 CFR 1910.304(b)(3)(i) · Grounding and circuit protection
Serious$0$0Dec 16, 2015Final
Citation 1, item 7
29 CFR 1910.304(b)(4) · Grounding and circuit protection
Serious$0$0Dec 16, 2015Final
Citation 1, item 8
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Dec 16, 2015Final

Inspection 306984634 OPENED OCT 7, 2008Closed

Follow-up · Partial · Safety · Local government · 15 employees at the site · Closed Oct 7, 2008

1 Walt Cole Blvd, Washingtonville, NY 10992 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306984238 OPENED JUL 29, 2008Closed

Monitoring · Partial · Safety · Local government · 15 employees at the site · Closed Oct 7, 2008

1 Walt Cole Blvd, Washingtonville, NY 10992 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306983602 OPENED MAR 7, 2008Closed

Planned · Complete · Safety · Local government · 15 employees at the site · Closed Oct 7, 2008

1 Walt Cole Blvd, Washingtonville, NY 10992 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Serious$0$0Apr 15, 2008Closed
Citation 1, item 2
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$0$0Apr 15, 2008Closed
Citation 1, item 3
29 CFR 1910.106(g)(3)(iii) · Flammable liquids
Serious$0$0Apr 15, 2008Closed
Citation 1, item 4
29 CFR 1910.212(b) · Machine guarding
Serious$0$0Apr 15, 2008Closed
Citation 1, item 5
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Apr 15, 2008Closed
Citation 1, item 6
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Apr 15, 2008Closed
Citation 1, item 7
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$0$0Apr 15, 2008Closed
Citation 1, item 8
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Serious$0$0Apr 15, 2008Closed
Citation 1, item 9
29 CFR 1910.266(d)(1)(iv) · Logging operations
Serious$0$0Apr 15, 2008Closed
Citation 1, item 10
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$0$0Apr 15, 2008Closed
Citation 1, item 11
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$0$0Apr 15, 2008Closed
Citation 1, item 12
29 CFR 1910.304(b)(2) · Grounding and circuit protection
Serious$0$0Apr 15, 2008Closed
Citation 1, item 13
29 CFR 1910.304(e)(1)(iv) · Grounding and circuit protection
Serious$0$0Apr 15, 2008Closed
Citation 1, item 14
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Apr 15, 2008Closed
Citation 1, item 15
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Apr 15, 2008Closed
Citation 1, item 16
29 CFR 1910.334(a)(3)(ii) · Using electrical equipment
Serious$0$0Apr 15, 2008Closed
Citation 2, item 1
29 CFR 1910.22(b)(1) · General requirements
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 2
29 CFR 1910.22(c) · General requirements
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 3
29 CFR 1910.120(l)(1)(i) · Hazardous waste operations and emergency response
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 4
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 5
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 6
29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 7
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 8
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 9
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 10
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 11
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Apr 15, 2008Closed
Citation 2, item 12
29 CFR 8010032 A02
Other-than-serious$0$0Apr 15, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(g)(3)(iii)

(iii) Emergency power cutoff. A clearly identified and easily accessible switch(es) or a circuit breaker(s) shall be provided at a location remote from dispensing devices, including remote pumping systems, to shut off the power to all dispensing devices in the event of an emergency.

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.120(l)(1)(i)

(l) Emergency response by employees at uncontrolled hazardous waste sites—(1) Emergency response plan. (i) An emergency response plan shall be developed and implemented by all employers within the scope of paragraphs (a)(1) (i)-(ii) of this section to handle anticipated emergencies prior to the commencement of hazardous waste operations. The plan shall be in writing and available for inspection and copying by employees, their representatives, OSHA personnel and other governmental agencies with relevant responsibilities.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.266 · Logging operations

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other highway, street, and bridge construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.