Waskey Bridges, Inc. has 8 OSHA inspections on record in Louisiana, the first in 1975.
OSHA's last visit started on Jul 17, 2023 after a complaint, in Baton Rouge.
Across those inspections OSHA issued 20 citation items: 8 serious and 12 other-than-serious.
OSHA proposed $25,691 in penalties. After settlements and reviews the total is $10,158, down 60%.
Most often, OSHA cited 1910.1200, hazard communication (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Waskey Bridges, Inc. averages $8,337 over 1 cited inspection in that time.
Waskey Bridges, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Louisiana · latest 90 days of OSHA records
18employers cited
Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Baton Rouge site logged 0 recordable injuries or illnesses among about 128 workers: 0.0 per 100 full-time workers, against a median of 3.4 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Waskey Bridges, Inc.
Baton Rouge · 2020
128
0
0
0.0
3.4
Included with any plan: 4 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
An employee was conducting concrete work while standing outside on a concrete platform. A form constructed of aluminum and wood fell and fractured the employee's right leg.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.
(iii) Emergency power cutoff. A clearly identified and easily accessible switch(es) or a circuit breaker(s) shall be provided at a location remote from dispensing devices, including remote pumping systems, to shut off the power to all dispensing devices in the event of an emergency.
29 CFR 1910.106(g)(9)
(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.
Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.