OSHA SearchOSHA records by employer

Wasson Commercial Contracting LLC: OSHA inspections and violations

Tempe, Arizona · Commercial and Institutional Building Construction · NAICS 236220

3inspections
4citation items
$750current penalties
May 14, 2018last inspection

Since 2016, OSHA inspectors have visited Wasson Commercial Contracting LLC in Arizona 3 times.

The most recent inspection opened on May 14, 2018 as part of a related case, in Glendale.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $750 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Wasson Commercial Contracting LLC averages $750 across 1 cited inspection.

Wasson Commercial Contracting LLC: OSHA citation items per year, 2016 to 2018
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

80employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Wasson Commercial Contracting LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343165221 OPENED MAY 14, 2018Closed

Unprogrammed related · Partial · Safety · 3 employees at the site · Closed May 14, 2018

9340 W Northern Ave, Glendale, AZ 85305 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Incident on May 14, 2018: Employee's back is fractured by falling trusses

At 12:39 p.m. on May 14, 2018, Employee #1, employed by a construction company, was inspecting trusses being installed for a new one-story commercial building. The trusses fell and struck Employee #1. He was transported to the hospital, admitted, and treated for a fractured back.

No citations from this inspection.

Inspection 342202785 OPENED MAR 23, 2017Closed

Planned · Complete · Safety · 1 employee at the site · Closed Mar 23, 2017

6488 W. Oracle Rd, Tucson, AZ 85704 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341406650 OPENED APR 14, 2016Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Sep 29, 2016

1783 W University Dr, Tempe, AZ 85281 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$750$750Jul 5, 2016Final
Citation 1, item 1b
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$0$0Jul 5, 2016Final
Citation 1, item 1c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jul 5, 2016Final
Citation 1, item 1d
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Jul 5, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.