OSHA SearchOSHA records by employer

Watts Crane LLC: OSHA inspections and violations

Brunswick, Maryland · All Other Specialty Trade Contractors · NAICS 238990

1inspections
8citation items
$7,400current penalties
Nov 3, 2022last inspection

OSHA has inspected Watts Crane LLC once in Maryland.

The inspection began on Nov 3, 2022 as a planned inspection, in Brunswick; the case is still open.

That inspection ended with 8 citation items: 4 serious, 2 repeat and 2 other-than-serious.

Penalties were first proposed at $7,400 and still stand at $7,400.

Wire rope—inspection comes up most often in these citations: 4 items under 1926.1413.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Watts Crane LLC averages $7,400 (1 cited inspection).

Watts Crane LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

195employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Watts Crane LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346322035 OPENED NOV 3, 2022Open

Planned · Complete · Safety · 2 employees at the site · Open

21 Karn Pl, Brunswick, MD 21716 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1413(b)(1) · Wire rope—inspection
Serious$1,000$1,000Dec 14, 2022Final
Citation 1, item 1b
29 CFR 1926.1413(c)(1) · Wire rope—inspection
Serious$0$0Dec 14, 2022Final
Citation 1, item 2
29 CFR 1926.1427(a) · Operator training, certification, and evaluation
Serious$1,000$1,000Dec 14, 2022Final
Citation 1, item 3
29 CFR 1926.1433(d)(3) · Design, construction and testing
Serious$1,000$1,000Dec 14, 2022Final
Citation 2, item 1
29 CFR 1926.1412(f)(1) · Inspections
Repeat$4,000$4,000Dec 14, 2022Final
Citation 3, item 1
29 CFR 1926.1413(b)(4) · Wire rope—inspection
Repeat$400$400Dec 14, 2022Final
Citation 4, item 1
29 CFR 1926.1412(f)(7) · Inspections
Other-than-serious$0$0Dec 14, 2022Final
Citation 4, item 2
29 CFR 1926.1413(c)(4) · Wire rope—inspection
Other-than-serious$0$0Dec 14, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1412 · Inspections

29 CFR 1926.1412(f)(1)

(f) Annual/comprehensive. (1) At least every 12 months the equipment must be inspected by a qualified person in accordance with paragraph (d) of this section (each shift) except that the corrective action set forth in paragraphs (f)(4), (f)(5), and (f)(6) of this section must apply in place of the corrective action required by paragraphs (d)(2) and (d)(3) of this section.

29 CFR 1926.1412(f)(7)

(7) Documentation of annual/comprehensive inspection. The following information must be documented, maintained, and retained for a minimum of 12 months, by the employer that conducts the inspection:

29 CFR 1926.1413 · Wire rope—inspection

29 CFR 1926.1413(b)(1)

(b) Monthly inspection. (1) Each month an inspection must be conducted in accordance with paragraph (a) (shift inspection) of this section.

29 CFR 1926.1427 · Operator training, certification, and evaluation

29 CFR 1926.1433 · Design, construction and testing

Other all other specialty trade contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.