OSHA SearchOSHA records by employer

Watts Services, LLC: OSHA inspections and violations

Downingtown, Pennsylvania · Water and Sewer Line and Related Structures Construction · NAICS 237110

2inspections
5citation items
$20,482current penalties
Jan 11, 2024last inspection

Watts Services, LLC has 2 OSHA inspections on record in Pennsylvania, the first in 2019.

OSHA's last visit started on Jan 11, 2024 as a planned inspection, in Quakertown.

Across those inspections OSHA issued 5 citation items: 5 other-than-serious.

OSHA proposed $22,950 in penalties. After settlements and reviews the total is $20,482, down 11%.

Most often, OSHA cited 1926.651, excavations (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Watts Services, LLC averages $10,241 over 2 cited inspections in that time.

Watts Services, LLC: OSHA citation items per year, 2019 to 2024
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

300employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Watts Services, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347206906 OPENED JAN 11, 2024Closed

Planned · Partial · Safety · 26 employees at the site · Closed Jul 22, 2024

Paletown Rd, Quakertown, PA 18951 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Other-than-serious$6,171$4,937Jun 17, 2024Final
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Other-than-serious$6,171$4,937Jun 17, 2024Final

Inspection 344059621 OPENED JUN 5, 2019Closed

Referral · Partial · Safety · 12 employees at the site · Closed Dec 18, 2019

50 Peck Rd., Downingtown, PA 19335 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Jun 5, 2019: Employee is trapped in trench collapse and incurs minor abra

On June 5, 2019, Employee #1 and coworkers, employed by a water and sewer line construction company, were working in an excavation and installing a sanitary sewer line. The trench partially collapsed, and Employee #1 was trapped to his waist for approximately two hours before he was freed. The employee was treated for minor abrasions. He did not require hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(h)(1) · Excavations
Other-than-serious$5,304$5,304Dec 3, 2019Final
Citation 1, item 1b
29 CFR 1926.651(k)(2) · Excavations
Other-than-serious$0$0Dec 3, 2019Final
Citation 1, item 2
29 CFR 1926.652(g)(2) · Trench protection
Other-than-serious$5,304$5,304Dec 3, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(h)(1)

(h) Protection from hazards associated with water accumulation. (1) Employees shall not work in excavations in which there is accumulated water, or in excavations in which water is accumulating, unless adequate precautions have been taken to protect employees against the hazards posed by water accumulation. The precautions necessary to protect employees adequately vary with each situation, but could include special support or shield systems to protect from cave-ins, water removal to control the level of accumulating water, or use of a safety harness and lifeline.

29 CFR 1926.651(k)(2)

(2) Where the competent person finds evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees shall be removed from the hazardous area until the necessary precautions have been taken to ensure their safety.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.