OSHA SearchOSHA records by employer

WD Masonry, LLC: OSHA inspections and violations

Denham Springs, Louisiana · Masonry Contractors · NAICS 238140

6inspections
22citation items
$77,167current penalties
Mar 5, 2021last inspection

Since 2009, OSHA inspectors have visited WD Masonry, LLC in Louisiana 6 times.

The most recent inspection opened on Mar 5, 2021 as a planned inspection, in Gonzales.

In all, OSHA issued 22 citation items: 18 serious, 3 repeat and 1 other-than-serious.

The proposed penalties came to $91,499; today they stand at $77,167, 16% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 15 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. WD Masonry, LLC averages $25,072 across 3 cited inspections.

The Wage and Hour Division has 1 case on it since 2015, with $908 in back wages owed to workers.

WD Masonry, LLC: OSHA citation items per year, 2009 to 2021
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

19employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch WD Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345180665 OPENED MAR 5, 2021Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jan 30, 2026

577 West Hwy 30, Gonzales, LA 70737 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$5,461$5,461May 5, 2021Final
Citation 1, item 1b
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$0$0May 5, 2021Final
Citation 1, item 1c
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0May 5, 2021Final
Citation 1, item 1d
29 CFR 1926.451(e)(2)(ii) · Scaffolds, general requirements
Serious$0$0May 5, 2021Final
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$5,461$5,461May 5, 2021Final
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0May 5, 2021Final
Citation 1, item 3
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$5,461$5,461May 5, 2021Final
Citation 1, item 4
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,901$3,901May 5, 2021Final
Citation 1, item 5a
29 CFR 1926.454(a) · Scaffold training
Serious$5,461$5,461May 5, 2021Final
Citation 1, item 5b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0May 5, 2021Final
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$6,242$6,242May 5, 2021Final
Citation 2, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$27,306$27,306May 5, 2021Final

Inspection 344889910 OPENED AUG 17, 2020Closed

Planned · Partial · Safety · 10 employees at the site · Closed Sep 29, 2023

9700 Florida Blvd, Baton Rouge, LA 70815 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,892$2,892Jan 12, 2021Final

Inspection 341836856 OPENED OCT 13, 2016Closed

Complaint · Partial · Safety · 45 employees at the site · Closed Nov 27, 2018

925 West Edenborne Pkwy, Gonzales, LA 70737 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$9,603$4,802Nov 18, 2016Final
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$16,461$8,230Nov 18, 2016Final

Inspection 313027187 OPENED OCT 22, 2009Closed

Planned · Partial · Safety · 14 employees at the site · Closed Mar 2, 2010

3090 Hwy 190 W, Hammond, LA 70401 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,125$675Jan 25, 2010Closed

Inspection 313025272 OPENED AUG 13, 2009Closed

Planned · Partial · Safety · 15 employees at the site · Closed Sep 16, 2009

12470 Brown Rd., Denham Springs, LA 70726 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$500$300Sep 8, 2009Closed
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$625$375Sep 8, 2009Closed
Citation 1, item 2b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Sep 8, 2009Closed
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$500$300Sep 8, 2009Closed
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$500$300Sep 8, 2009Closed

Inspection 313022360 OPENED APR 7, 2009Closed

Planned · Complete · Safety · 45 employees at the site · Closed Jun 29, 2009

12470 Brown Road, Denham Springs, LA 70726 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$0$0Jun 24, 2009Closed

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Jun 30, 2018 to Jul 13, 2018
Baton Rouge
41$908$1,365

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.