We Install Floors LLC: OSHA inspections and violations

Honolulu, Hawaii · Flooring Contractors · NAICS 238330

1inspections
2citation items
$4,434current penalties
Feb 6, 2018last inspection

OSHA has inspected We Install Floors LLC once in Hawaii.

The inspection began on Feb 6, 2018, in Honolulu.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $4,434 and still stand at $4,434.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and We Install Floors LLC averages $4,434 (1 cited inspection).

We Install Floors LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

62employers cited

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch We Install Floors LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342935418 OPENED FEB 6, 2018Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed Nov 9, 2018

2470 Kalakaua Avenue, Honolulu, HI 96815 · Flooring Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$2,217$2,217Apr 3, 2018Final
Citation 1, item 2
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$2,217$2,217Apr 3, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other flooring contractors employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.