Weakley County - Senior Center: OSHA inspections and violations

Dresden, Tennessee · Services for the Elderly and Persons with Disabilities · NAICS 624120

1inspections
4citation items
$0current penalties
Apr 26, 2023last inspection

OSHA inspectors have visited Weakley County - Senior Center in Tennessee one time.

It opened on Apr 26, 2023 as a planned inspection, in Dresden.

In all, OSHA issued 4 citation items: 4 serious.

No penalty came with these citations.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 2 times.

Among health care employers, the typical cited inspection since 2015 ends with a $1,050 penalty. Weakley County - Senior Center averages $0 across 1 cited inspection.

Weakley County - Senior Center: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

339employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Weakley County - Senior Center and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346658529 OPENED APR 26, 2023Closed

Planned · Complete · Safety · Local government · 7 employees at the site · Closed May 31, 2023

598 Evergreen Street, Dresden, TN 38225 · Services for the Elderly and Persons with Disabilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0May 2, 2023Final
Citation 1, item 2
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0May 2, 2023Final
Citation 1, item 3
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0May 2, 2023Final
Citation 1, item 4
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0May 2, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(g)(5)

(5) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.

29 CFR 1910.305 · Electrical wiring methods

Other services for the elderly and persons with disabilities employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.