Inspection 341449635 OPENED MAY 2, 2016Closed
12555 W. 52nd Ave, Arvada, CO 80002 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2016, OSHA inspectors have visited Weatherford Laboratories, Inc. in Colorado 2 times.
The most recent inspection opened on May 2, 2016 after a complaint, in Arvada.
In all, OSHA issued 2 citation items: 2 serious.
The proposed penalties came to $2,800; today they stand at $1,680, 40% less.
The rule cited most here is 1910.106 (flammable liquids), 2 times.
Among mining and oil and gas employers, the typical cited inspection since 2015 ends with a $2,886 penalty. Weatherford Laboratories, Inc. averages $1,680 across 1 cited inspection.
Colorado · latest 90 days of OSHA records
142employers cited
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Colorado
Checking a subcontractor, a client or your own company? Watch Weatherford Laboratories, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company12555 W. 52nd Ave, Arvada, CO 80002 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
16161 Table Mountain Pkwy, Golden, CO 80403 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.106(e)(6)(i) · Flammable liquids |
Serious | $2,800 | $1,680 | Jun 2, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.106(e)(6)(ii) · Flammable liquids |
Serious | $0 | $0 | Jun 2, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(e)(6)(i)
(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.