OSHA SearchOSHA records by employer

Weathers Construction, Inc.: OSHA inspections and violations

Columbus, Mississippi · Masonry Contractors · NAICS 238140

5inspections
10citation items
$12,455current penalties
Jul 13, 2021last inspection

Since 2014, OSHA inspectors have visited Weathers Construction, Inc. in Mississippi 5 times.

The most recent inspection opened on Jul 13, 2021 as a planned inspection, in Columbus.

In all, OSHA issued 10 citation items: 8 serious and 2 other-than-serious.

The proposed penalties came to $20,758; today they stand at $12,455, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Weathers Construction, Inc. averages $3,335 across 2 cited inspections.

Weathers Construction, Inc.: OSHA citation items per year, 2014 to 2021
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

16employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Weathers Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345420582 OPENED JUL 13, 2021Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jul 28, 2021

311 Tuscaloosa Road, Columbus, MS 39705 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343773420 OPENED FEB 8, 2019Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 11, 2019

509 University Drive, Starkville, MS 39759 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$3,978$2,387Mar 5, 2019Final

Inspection 341346369 OPENED MAR 22, 2016Closed

Planned · Partial · Safety · 31 employees at the site · Closed Mar 25, 2016

111 Confederate Dr., Caledonia, MS 39740 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341095933 OPENED DEC 3, 2015Closed

Planned · Complete · Safety · 9 employees at the site · Closed Dec 22, 2015

505 2nd Avenue North, Columbus, MS 39701 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$2,380$1,428Dec 15, 2015Final
Citation 1, item 2
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$2,380$1,428Dec 15, 2015Final
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$2,380$1,428Dec 15, 2015Final

Inspection 339609380 OPENED FEB 25, 2014Closed

Planned · Partial · Safety · 7 employees at the site · Closed Apr 17, 2014

2031 Us Hwy 45 North, Columbus, MS 39705 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,142$1,285Apr 7, 2014Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,678$1,607Apr 7, 2014Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,678$1,607Apr 7, 2014Final
Citation 1, item 4
29 CFR 1926.452(w)(1) · Rules for each type of scaffold
Serious$2,142$1,285Apr 7, 2014Final
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Apr 7, 2014Final
Citation 2, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Other-than-serious$0$0Apr 7, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.