OSHA SearchOSHA records by employer

Weber Roofing: OSHA inspections and violations

Mount Lebanon, Pennsylvania · Roofing Contractors · NAICS 238160

1inspections
5citation items
$2,800current penalties
Jan 17, 2023last inspection

Weber Roofing has one OSHA inspection on record in Pennsylvania.

OSHA opened it on Jan 17, 2023 after a complaint, in Mount Lebanon.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $5,358 in penalties. After settlements and reviews the total is $2,800, down 48%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Weber Roofing averages $2,800 over 1 cited inspection in that time.

Weber Roofing: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Weber Roofing again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346443856 OPENED JAN 17, 2023Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Sep 25, 2025

220 Baywood Road, Mount Lebanon, PA 15228 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,679$1,400Jan 31, 2023Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jan 31, 2023Final
Citation 1, item 1c
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$0$0Jan 31, 2023Final
Citation 1, item 1d
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$0$0Jan 31, 2023Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,679$1,400Jan 31, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Pennsylvania