OSHA SearchOSHA records by employer

Webster Electric Company. Inc.: OSHA inspections and violations

Meridian, Mississippi · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

8inspections
6citation items
$7,867current penalties
Sep 4, 2020last inspection

Since 2005, OSHA inspectors have visited Webster Electric Company. Inc. in Mississippi 8 times.

The most recent inspection opened on Sep 4, 2020 as a planned inspection, in Louisville.

In all, OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

The proposed penalties came to $16,829; today they stand at $7,867, 53% less.

The rule cited most here is 1926.405 (job-site wiring), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Webster Electric Company. Inc. averages $4,817 across 1 cited inspection.

Webster Electric Company. Inc.: OSHA citation items per year, 2005 to 2020
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

24employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Webster Electric Company. Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344916119 OPENED SEP 4, 2020Closed

Planned · Complete · Safety · 5 employees at the site · Closed Dec 22, 2020

South Court Avenue, Louisville, MS 39339 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$3,441$2,065Oct 28, 2020Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$4,588$2,753Oct 28, 2020Final

Inspection 343674859 OPENED DEC 11, 2018Closed

Planned · Complete · Safety · 7 employees at the site · Closed Feb 6, 2019

11200 Highway 182 East, Starkville, MS 39759 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341648715 OPENED JUL 26, 2016Closed

Planned · Complete · Safety · 9 employees at the site · Closed Aug 29, 2016

1524 Highway 19 North, Meridian, MS 39301 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340442714 OPENED MAR 4, 2015Closed

Referral · Partial · Safety · 5 employees at the site · Closed Nov 6, 2015

Intersection Of Capitol And Congress St., Jackson, MS 39269 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313633364 OPENED OCT 6, 2010Closed

Planned · Partial · Safety · 3 employees at the site · Closed May 11, 2012

Hwy 90, Gautier, MS 39553 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Other-than-serious$4,900$0Oct 25, 2010Final

Inspection 311417109 OPENED OCT 16, 2008Closed

Planned · Partial · Safety · 200 employees at the site · Closed Nov 28, 2008

Bruce Campbell Field, Madison, MS 39110 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$1,750$1,000Nov 4, 2008Closed
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,400$800Nov 4, 2008Closed

Inspection 308773522 OPENED DEC 6, 2006Closed

Planned · Partial · Safety · 10 employees at the site · Closed Mar 2, 2007

401 Arrow Dr., Clinton, MS 39056 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$750$1,250Jan 26, 2007Closed

Inspection 308767870 OPENED JUL 8, 2005Closed

Unprogrammed related · Complete · Safety · 5 employees at the site · Closed Jul 19, 2005

2200 5th Street, Meridian, MS 39301 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.503 · Fall protection training in construction

Other electrical contractors and other wiring installation contractors employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.