OSHA SearchOSHA records by employer

Wecare Denali LLC: OSHA inspections and violations

Fort Myers, Florida · Materials Recovery Facilities · NAICS 562920

1inspections
2citation items
$14,502current penalties
Jun 13, 2022last inspection

Wecare Denali LLC has one OSHA inspection on record in Florida.

OSHA opened it on Jun 13, 2022 after a fatality or catastrophe, in Fort Myers, and the case has not closed yet.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $14,502 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.333, working near live electrical parts (2 items).

For context, across all staffing, cleaning and waste services employers the median penalty per cited inspection since 2015 is $2,208. Wecare Denali LLC averages $14,502 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Wecare Denali LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Wecare Denali LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346015563 OPENED JUN 13, 2022Open

Fatality or catastrophe · Complete · Safety · 227 employees at the site · Open

23715 Linda Lee Way, Fort Myers, FL 33913 · Materials Recovery Facilities · OSHA's record · Phone and website on Google Maps

Incident on Jun 13, 2022 (fatal): Employee is killed by electrocution

At 11:00 a.m. on June 13, 2022, an employee was delivering compost loaded in the bed of a grapple truck. The employee was working in a two-man crew and was being trained to operate the grapple truck. A coworker was operating the hydraulic grapple and inadvertently swung the grapple into 14.4 kV overhead power lines. The employee was climbing out of truck cab at the same moment the grapple contacted the power lines. The employee was killed by electrocution.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.333(c)(3)(iii)(a) · Working near live electrical parts
Serious$14,502$14,502Oct 3, 2022Final
Citation 1, item 1b
29 CFR 1910.333(c)(3)(i)(a)(1) · Working near live electrical parts
Serious$0$0Oct 3, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(c)(3)(i)(a)(1)

(i) Unqualified persons. (A) When an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances:

29 CFR 1910.333(c)(3)(iii)(a)

(iii) Vehicular and mechanical equipment. (A) Any vehicle or mechanical equipment capable of having parts of its structure elevated near energized overhead lines shall be operated so that a clearance of 10 ft. (305 cm) is maintained. If the voltage is higher than 50kV, the clearance shall be increased 4 in. (10 cm) for every 10kV over that voltage. However, under any of the following conditions, the clearance may be reduced:

Other materials recovery facilities employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.