OSHA SearchOSHA records by employer

West End Machine & Welding, Inc.: OSHA inspections and violations

Richmond, Virginia · Machine Shops · NAICS 332710

7inspections
34citation items
$7,706current penalties
Oct 30, 2018last inspection

Since 1998, OSHA inspectors have visited West End Machine & Welding, Inc. in Virginia 7 times.

The most recent inspection opened on Oct 30, 2018 on a referral, in Ashland.

In all, OSHA issued 34 citation items: 20 serious and 14 other-than-serious.

The proposed penalties came to $8,960; today they stand at $7,706, 14% less.

The rule cited most here is 1910.1200 (hazard communication), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. West End Machine & Welding, Inc. averages $2,440 across 2 cited inspections.

West End Machine & Welding, Inc.: OSHA citation items per year, 1998 to 2018
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch West End Machine & Welding, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343569794 OPENED OCT 30, 2018Closed

Referral · Partial · Safety · 40 employees at the site · Closed Jan 11, 2019

Food Lion Store 253 N. Washington Hwy, Ashland, VA 23005 · Machine Shops · OSHA's record · Phone and website on Google Maps

Incident on Oct 26, 2018: Employee sustains electrical shock from ceiling wires

At 11:45 p.m. on October 26, 2018, an employee was removing electrical wires from the ceiling and came into contact with live wires. The employee sustained an electrical shock and burned his hand. The employee was hospitalized. hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$4,880$4,880Dec 6, 2018Final
Citation 1, item 1b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$0$0Dec 6, 2018Final

Inspection 342367166 OPENED JUN 1, 2017Closed

Planned · Complete · Health · 25 employees at the site · Closed Aug 3, 2017

6804 School Ave, Richmond, VA 23228 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Jul 10, 2017Final

Inspection 316643923 OPENED AUG 15, 2012Closed

Follow-up · Partial · Safety · 1 employee at the site · Closed Aug 20, 2012

629 East Main Street, Richmond, VA 23219 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316492099 OPENED APR 23, 2012Closed

Referral · Partial · Safety · 3 employees at the site · Closed Aug 21, 2012

629 East Main Street, Richmond, VA 23219 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.50(c) · Medical services and first aid
Serious$315$220May 24, 2012Closed
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$315$220May 24, 2012Closed
Citation 1, item 3a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$735$514May 24, 2012Closed
Citation 1, item 3b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0May 24, 2012Closed
Citation 1, item 4
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$315$220May 24, 2012Closed

Inspection 313808222 OPENED SEP 11, 2009Closed

Planned · Complete · Health · 20 employees at the site · Closed Oct 27, 2009

6804 School Avenue, Richmond, VA 23228 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(6) · Exit routes
Serious$225$135Sep 28, 2009Closed
Citation 1, item 2a
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$300$180Sep 28, 2009Closed
Citation 1, item 2b
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Sep 28, 2009Closed
Citation 1, item 3a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$225$135Sep 28, 2009Closed
Citation 1, item 3b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Sep 28, 2009Closed
Citation 2, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Sep 28, 2009Closed
Citation 2, item 2
29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens
Other-than-serious$0$0Sep 28, 2009Closed
Citation 2, item 3
29 CFR 1910.1052(d)(2) · Methylene chloride
Other-than-serious$0$0Sep 28, 2009Closed
Citation 2, item 4
29 CFR 1910.1052(l)(1) · Methylene chloride
Other-than-serious$0$0Sep 28, 2009Closed
Citation 2, item 5
29 CFR 1910.1200(e)(4) · Hazard communication
Other-than-serious$0$0Sep 28, 2009Closed
Citation 2, item 6
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Sep 28, 2009Closed

Inspection 304532195 OPENED NOV 25, 2002Closed

Planned · Complete · Safety · 23 employees at the site · Closed Jan 28, 2003

6804 School Avenue, Glen Allen, VA 23228 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$225$135Dec 19, 2002Closed
Citation 1, item 2
29 CFR 1910.212(b) · Machine guarding
Serious$225$135Dec 19, 2002Closed
Citation 1, item 3a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$225$135Dec 19, 2002Closed
Citation 1, item 3b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Dec 19, 2002Closed
Citation 1, item 4
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$225$135Dec 19, 2002Closed
Citation 1, item 5
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$225$135Dec 19, 2002Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Dec 19, 2002Closed
Citation 2, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Dec 19, 2002Closed
Citation 2, item 3
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 19, 2002Closed
Citation 2, item 4
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Dec 19, 2002Closed
Citation 2, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Dec 19, 2002Closed
Citation 2, item 6
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Dec 19, 2002Closed
Citation 2, item 7
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Dec 19, 2002Closed

Inspection 301818019 OPENED MAR 27, 1998Closed

Referral · Partial · Safety · 4 employees at the site · Closed Dec 15, 1998

1500 East Main Street, Richmond, VA 23219 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.50(c) · Medical services and first aid
Serious$225$225Apr 1, 1998Closed
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$300$300Apr 1, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(i)

(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.

29 CFR 1910.1052 · Methylene chloride

29 CFR 1910.1052(d)(2)

(2) Initial determination. Each employer whose employees are exposed to MC shall perform initial exposure monitoring to determine each affected employee's exposure, except under the following conditions:

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other machine shops employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.