OSHA SearchOSHA records by employer

Westerfield Electric LLC: OSHA inspections and violations

Owensboro, Kentucky · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

5inspections
3citation items
$3,500current penalties
Oct 17, 2018last inspection

Westerfield Electric LLC has 5 OSHA inspections on record in Kentucky, the first in 2007.

OSHA's last visit started on Oct 17, 2018, in Owensboro.

Across those inspections OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $5,250 in penalties. After settlements and reviews the total is $3,500, down 33%.

Most often, OSHA cited 1926.405, job-site wiring (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Westerfield Electric LLC averages $1,750 over 2 cited inspections in that time.

Westerfield Electric LLC also files yearly injury logs with OSHA, summarized below.

Westerfield Electric LLC: OSHA citation items per year, 2007 to 2018
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

180employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Westerfield Electric LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343545638 OPENED OCT 17, 2018Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed May 7, 2019

2700 Calumet Trace, Owensboro, KY 42303 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii)(b) · Job-site wiring
Serious$1,750$1,750Feb 22, 2019Final

Inspection 341700102 OPENED AUG 11, 2016Closed

Unprogrammed related · Partial · Safety · 12 employees at the site · Closed Feb 10, 2017

2920 Wimsatt Court, Saint Joseph, KY 42301 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,500$1,750Dec 20, 2016Final

Inspection 316866920 OPENED APR 17, 2013Closed

Unprogrammed related · Complete · Safety · 25 employees at the site · Closed Mar 25, 2014

610 W. 2nd Street, Owensboro, KY 42301 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$0$0Jul 17, 2013Closed

Inspection 316533306 OPENED DEC 10, 2012Closed

Unprogrammed other · Complete · Safety · 12 employees at the site · Closed Jan 4, 2013

1300 Daniels Ln., Owensboro, KY 42303 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310655840 OPENED MAR 6, 2007Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Mar 6, 2007

3500 Villa Dr, Owensboro, KY 42303 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the Owensboro site logged 0 recordable injuries or illnesses among about 17 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Westerfield Electric LLC
Owensboro · 2021
17 000.01.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(b)

(B) Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

Other electrical contractors and other wiring installation contractors employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.