OSHA SearchOSHA records by employer

Western Diversified Plastics: OSHA inspections and violations

Mattawan, Michigan · All Other Plastics Product Manufacturing · NAICS 326199

4inspections
3citation items
$1,050current penalties
Mar 31, 2025last inspection

Western Diversified Plastics has 4 OSHA inspections on record in Michigan, the first in 2018.

OSHA's last visit started on Mar 31, 2025 after a complaint, in Mattawan.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $2,100 in penalties. After settlements and reviews the total is $1,050, down 50%.

Most often, OSHA cited 1910.147, lockout/tagout (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Western Diversified Plastics averages $1,050 over 1 cited inspection in that time.

Western Diversified Plastics also files yearly injury logs with OSHA, summarized below.

Western Diversified Plastics: OSHA citation items per year, 2018 to 2025
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

656employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Western Diversified Plastics and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348145418 OPENED MAR 31, 2025Closed

Complaint · Partial · Safety · 750 employees at the site · Closed May 27, 2025

53150 North Main Street, Mattawan, MI 49071 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$2,100$1,050May 1, 2025Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0May 1, 2025Final
Citation 1, item 1c
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0May 1, 2025Final

Inspection 347444713 OPENED APR 29, 2024Closed

Complaint · Partial · Health · 50 employees at the site · Closed Jun 18, 2024

53160 N. Main Street, Mattawan, MI 49071 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345194310 OPENED MAR 12, 2021Closed

Planned · Partial · Safety · 400 employees at the site · Closed Mar 31, 2021

53150 N Main St, Mattawan, MI 49071 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342843661 OPENED JAN 8, 2018Closed

Referral · Partial · Safety · 500 employees at the site · Closed Jan 30, 2018

53150 N Main St, Mattawan, MI 49071 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Mattawan site logged 15 recordable injuries or illnesses among about 844 workers: 1.8 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 439 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Western Diversified Plastics
Mattawan · 2025
844 1571.82.6
Western Diversified Plastics, LLC
Mattawan · 2024
809 2082.32.6
Mattawan N. Main Facility
Mattawan · 2024
809 2082.32.6

Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

Other all other plastics product manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.