Inspection 347040727 OPENED OCT 17, 2023Closed
11060 Irma Drive, North Glenn, CO 80233 · Metal Crown, Closure, and Other Metal Stamping (except Automotive) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
North Glenn, Colorado · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999
OSHA has inspected White Rock Manufacturing Solutions LLC 2 times in Colorado since 2022.
The latest one began on Oct 17, 2023 to follow up on an earlier case, in North Glenn.
Those inspections ended with 3 citation items: 2 serious and 1 other-than-serious.
Penalties were first proposed at $20,092 and now stand at $10,046, 50% lower after settlements or reviews.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and White Rock Manufacturing Solutions LLC averages $10,046 (1 cited inspection).
Colorado · latest 90 days of OSHA records
142employers cited
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Colorado
Checking a subcontractor, a client or your own company? Watch White Rock Manufacturing Solutions LLC and get notified the morning OSHA posts a new citation for it.
Watch this company11060 Irma Drive, North Glenn, CO 80233 · Metal Crown, Closure, and Other Metal Stamping (except Automotive) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
11060 Irma Drive, North Glenn, CO 80233 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1026(d)(1) · Hexavalent chromium |
Serious | $10,046 | $5,023 | Apr 27, 2023 | Final |
| Citation 1, item 2 29 CFR 1910.1200(h)(3) · Hazard communication |
Serious | $10,046 | $5,023 | Apr 27, 2023 | Final |
| Citation 2, item 1 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 27, 2023 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1026(d)(1)
(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.
29 CFR 1910.1200(h)(3)
(3) Training. Employee training shall include at least:
29 CFR 1910.134(c)(2)(i)
(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and