Wholesale Lumber Co. / do it Best Hardware: OSHA inspections and violations

Clint, Texas · Home Centers · NAICS 444110

1inspections
4citation items
$7,000current penalties
Jun 17, 2024last inspection

OSHA inspectors have visited Wholesale Lumber Co. / do it Best Hardware in Texas one time.

It opened on Jun 17, 2024 after a complaint, in Clint.

In all, OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

The proposed penalties came to $10,256; today they stand at $7,000, 32% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 3 times.

Among retail employers, the typical cited inspection since 2015 ends with a $1,750 penalty. Wholesale Lumber Co. / do it Best Hardware averages $7,000 across 1 cited inspection.

Wholesale Lumber Co. / do it Best Hardware: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Wholesale Lumber Co. / do it Best Hardware and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347556896 OPENED JUN 17, 2024Closed

Complaint · Partial · Health · 12 employees at the site · Closed Aug 15, 2024

12298 Alameda Avenue, Clint, TX 79836 · Home Centers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$4,610$3,000Jul 23, 2024Final
Citation 1, item 2
29 CFR 1910.303(c)(3)(i) · Electrical equipment, general requirements
Serious$4,610$3,000Jul 23, 2024Final
Citation 2, item 1
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Other-than-serious$518$500Jul 23, 2024Final
Citation 2, item 2
29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods
Other-than-serious$518$500Jul 23, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.303(c)(3)(i)

(3) Splices. (i) Conductors shall be spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.