OSHA SearchOSHA records by employer

WHY Hospitality, LLC.: OSHA inspections and violations

Phoenix, Arizona · Commercial and Institutional Building Construction · NAICS 236220

3inspections
8citation items
$1,500current penalties
Oct 22, 2015last inspection

Since 2012, OSHA inspectors have visited WHY Hospitality, LLC. in Arizona 3 times.

The most recent inspection opened on Oct 22, 2015 as a planned inspection, in Tempe.

In all, OSHA issued 8 citation items: 2 serious and 6 other-than-serious.

The penalties, $1,500 in total, stand where OSHA first set them.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. WHY Hospitality, LLC. averages $750 across 1 cited inspection.

WHY Hospitality, LLC.: OSHA citation items per year, 2012 to 2015
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

86employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch WHY Hospitality, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341006526 OPENED OCT 22, 2015Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jul 11, 2016

1550 S 52nd St, Tempe, AZ 85281 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$750$750Mar 14, 2016Final

Inspection 317857431 OPENED SEP 11, 2014Closed

Unprogrammed related · Complete · Safety · 5 employees at the site · Closed Nov 24, 2014

1890 E Ash St, Globe, AZ 85501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Other-than-serious$0$0Nov 17, 2014Closed
Citation 1, item 2
29 CFR 1926.405(a)(2)(iif) · Job-site wiring
Other-than-serious$0$0Nov 17, 2014Closed

Inspection 316867886 OPENED NOV 19, 2012Closed

Complaint · Partial · Safety · 14 employees at the site · Closed May 28, 2015

4575 E Irma Ln, Phoenix, AZ 85050 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$750$750Jan 23, 2013Closed
Citation 2, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Jan 23, 2013Closed
Citation 2, item 2
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Jan 23, 2013Closed
Citation 2, item 3
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Jan 23, 2013Closed
Citation 2, item 4
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jan 23, 2013Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.150(c)(1)(viii)

(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other commercial and institutional building construction employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.