OSHA SearchOSHA records by employer

Will Vojnar: OSHA inspections and violations

Slingerlands, New York · Roofing Contractors · NAICS 238160

1inspections
3citation items
$2,173current penalties
Nov 1, 2017last inspection

Will Vojnar has one OSHA inspection on record in New York.

OSHA opened it on Nov 1, 2017 as a planned inspection, in Slingerlands.

From that inspection OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $2,173 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,078. Will Vojnar averages $2,173 over 1 cited inspection in that time.

Will Vojnar: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Will Vojnar again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342743762 OPENED NOV 1, 2017Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 30, 2022

728 Waysentha Way, Slingerlands, NY 12159 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,173$2,173Nov 2, 2017Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Nov 2, 2017Final
Citation 2, item 2
29 CFR 1926.150(c)(1)(vi) · Fire protection
Other-than-serious$0$0Nov 2, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(vi)

(vi) A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other roofing contractors employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.