OSHA SearchOSHA records by employer

Willamette Glass Inc: OSHA inspections and violations

Tigard, Oregon · Glass and Glazing Contractors · NAICS 238150

3inspections
5citation items
$6,120current penalties
May 11, 2026last inspection

Since 1996, OSHA inspectors have visited Willamette Glass Inc in Oregon 3 times.

The most recent inspection opened on May 11, 2026 as a planned inspection, in North Plains and is still open.

In all, OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

The penalties, $6,120 in total, stand where OSHA first set them.

The rule cited most here is 1926.1053 (ladders in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Willamette Glass Inc averages $6,120 across 1 cited inspection.

Willamette Glass Inc: OSHA citation items per year, 1996 to 2026
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

391employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Willamette Glass Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348929324 OPENED MAY 11, 2026Open

Planned · Partial · Safety · 18 employees at the site · Open

10875 Nw 311th Ave, North Plains, OR 97133 · Glass and Glazing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 348229824 OPENED APR 22, 2025Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 21, 2026

7367 Sw Bridgeport Rd, Tigard, OR 97224 · Glass and Glazing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-003-1501(1)
Serious$4,708$4,708May 19, 2025Final
Citation 1, item 2a
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$1,412$1,412May 19, 2025Final
Citation 1, item 2b
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0May 19, 2025Final
Citation 2, item 3
29 CFR OAR 437-001-0765(13)-1
Other-than-serious$0$0May 19, 2025Final
Citation 2, item 4
29 CFR OAR 437-003-0503(2)(B)
Other-than-serious$0$0May 19, 2025Final

Inspection 124697020 OPENED NOV 5, 1996Closed

Planned · Complete · Safety · 2 employees at the site · Closed Nov 6, 1996

1200 Sw 66th, Tigard, OR 97223 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

Other glass and glazing contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.