William Bayers Industries Inc: OSHA inspections and violations

Westland, Michigan · Motor Vehicle Metal Stamping · NAICS 336370

2inspections
15citation items
$4,200current penalties
Nov 8, 2017last inspection

William Bayers Industries Inc has 2 OSHA inspections on record in Michigan, the first in 2014.

OSHA's last visit started on Nov 8, 2017 as a planned inspection, in Westland.

Across those inspections OSHA issued 15 citation items: 6 serious and 9 other-than-serious.

OSHA proposed $8,400 in penalties. After settlements and reviews the total is $4,200, down 50%.

Most often, OSHA cited 1910.305, electrical wiring methods (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. William Bayers Industries Inc averages $4,200 over 1 cited inspection in that time.

William Bayers Industries Inc: OSHA citation items per year, 2014 to 2017
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

647employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch William Bayers Industries Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342758133 OPENED NOV 8, 2017Closed

Planned · Complete · Safety · 90 employees at the site · Closed May 9, 2018

39097 Webb Dr, Westland, MI 48185 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10121(1)
Serious$1,200$600Jan 25, 2018Final
Citation 1, item 2
29 CFR 408.10233(3)
Serious$1,200$600Jan 25, 2018Final
Citation 1, item 3
29 CFR 408.10711
Serious$1,500$750Jan 25, 2018Final
Citation 1, item 4
29 CFR 408.12442(1)
Serious$1,500$750Jan 25, 2018Final
Citation 1, item 5
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,500$750Jan 25, 2018Final
Citation 1, item 6
29 CFR 408.14009(9)
Serious$1,500$750Jan 25, 2018Final
Citation 2, item 1
29 CFR 408.10011(D)
Other-than-serious$0$0Jan 25, 2018Final
Citation 2, item 2
29 CFR 408.10015(1)
Other-than-serious$0$0Jan 25, 2018Final
Citation 2, item 3a
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 25, 2018Final
Citation 2, item 3b
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Jan 25, 2018Final
Citation 2, item 3c
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Jan 25, 2018Final
Citation 2, item 3d
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 25, 2018Final
Citation 2, item 4
29 CFR 408.14007(7)
Other-than-serious$0$0Jan 25, 2018Final
Citation 2, item 5
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0Jan 25, 2018Final
Citation 2, item 6 Other-than-serious$0$0Jan 25, 2018Final

Inspection 339955676 OPENED SEP 10, 2014Closed

Planned · Partial · Safety · 65 employees at the site · Closed Oct 9, 2014

39097 Webb Dr, Westland, MI 48185 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)

(6) Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:

29 CFR 1910.169 · Air receivers

29 CFR 1910.169(b)(3)(iii)

(iii) Safety appliances, such as safety valves, indicating devices and controlling devices, shall be constructed, located, and installed so that they cannot be readily rendered inoperative by any means, including the elements.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

29 CFR 1910.305 · Electrical wiring methods

Other motor vehicle metal stamping employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.