OSHA SearchOSHA records by employer

William J. O'Rourke, Inc.: OSHA inspections and violations

Latham, New York · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

3inspections
10citation items
$8,049current penalties
Jul 7, 2022last inspection

William J. O'Rourke, Inc. has 3 OSHA inspections on record in New York, the first in 2014.

OSHA's last visit started on Jul 7, 2022 as part of a related case, in Burnt Hills.

Across those inspections OSHA issued 10 citation items: 8 serious and 2 other-than-serious.

OSHA proposed $9,489 in penalties. After settlements and reviews the total is $8,049, down 15%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. William J. O'Rourke, Inc. averages $3,729 over 1 cited inspection in that time.

William J. O'Rourke, Inc.: OSHA citation items per year, 2014 to 2022
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch William J. O'Rourke, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346088636 OPENED JUL 7, 2022Closed

Unprogrammed related · Partial · Safety · 10 employees at the site · Closed Jan 17, 2023

11 Summerhill Dr., Burnt Hills, NY 12027 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,729$3,729Nov 29, 2022Final

Inspection 339942740 OPENED SEP 8, 2014Closed

Complaint · Complete · Safety · 12 employees at the site · Closed Nov 13, 2014

Riverview Road, Coeymans, NY 12045 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,080$810Oct 22, 2014Final
Citation 1, item 2
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$1,080$810Oct 22, 2014Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,080$810Oct 22, 2014Final
Citation 1, item 4a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,080$810Oct 22, 2014Final
Citation 1, item 4b
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Oct 22, 2014Final
Citation 1, item 4c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Oct 22, 2014Final
Citation 1, item 5
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,440$1,080Oct 22, 2014Final
Citation 2, item 1
29 CFR 1926.50(d)(1) · Medical services and first aid
Other-than-serious$0$0Oct 22, 2014Final
Citation 2, item 2
29 CFR 1926.150(c)(1)(vi) · Fire protection
Other-than-serious$0$0Oct 22, 2014Final

Inspection 339571135 OPENED FEB 3, 2014Closed

Planned · Complete · Safety · 7 employees at the site · Closed Feb 3, 2014

Canterbury Crossing Stacy Court, Building 3, Latham, NY 12110 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(vi)

(vi) A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other other foundation, structure, and building exterior contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.