OSHA SearchOSHA records by employer

Williams Industrial Services, LLC: OSHA inspections and violations

Austin, Texas · Petroleum Bulk Stations and Terminals · NAICS 424710

2inspections
2citation items
$24,290current penalties
May 21, 2020last inspection

Williams Industrial Services, LLC has 2 OSHA inspections on record in Texas, the first in 1994.

OSHA's last visit started on May 21, 2020 on a referral, in Galveston.

Across those inspections OSHA issued 2 citation items: 1 serious and 1 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1926.352, fire prevention (2 items).

For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,425. Williams Industrial Services, LLC averages $24,290 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Williams Industrial Services, LLC: OSHA citation items per year, 1994 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Williams Industrial Services, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344758529 OPENED MAY 21, 2020Closed

Referral · Complete · Safety · 21 employees at the site · Closed Jan 13, 2021

3801 Gti Blvd, Galveston, TX 77550 · Petroleum Bulk Stations and Terminals · OSHA's record · Phone and website on Google Maps

Incident on May 19, 2020: One employee falls, another is burned, when vapors ignite

At 3:15 p.m. on May 19, 2020, nine employees were at work. This investigation covered three firms, all in the same city. One firm constructed power lines, communication lines, and related structures. It had inspection number 1475852. Another firm was a temporary staffing employment agency. It had inspection number 1476196. The third firm operated a storage terminal. It had inspection number 1475880. This firm was operating a tank terminal for oils, gases, and chemicals. It appears that the temporary staffing employment agency had sent one or more of its employees to work for the construction firm at the storage tank site operated by the storage terminal. One or more employees had been instructed to weld in the presence of an explosive atmosphere while modifying an improperly prepared storage tank, storage tank 106-37. Pads were being welded onto the tank roof. The tank had contained low-sulfur vacuum gas oil. Flammable vapors were still present. The vapors ignited. An explosion occurred inside the tank followed by a fire. One employee fell 40 feet (12.2 meters). He suffered a fractured hip or pelvis and a fractured arm when he struck the ground. A second employee, working as a helper, suffered burns. Those two employees were hospitalized for two or more days. The other seven employee were either not injured at all or were treated without hospitalization. The narrative did not clarify what each of the nine workers was doing at the time of the incident. The incident was covered by one UPA, number 1593040. The storage terminal received the citations.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1926.352(c) · Fire prevention
Serious$0$12,145Oct 23, 2020Final
Citation 1, item 2b
29 CFR 1926.352(e) · Fire prevention
Other-than-serious$0$12,145Oct 23, 2020Final

Inspection 123548679 OPENED JUN 30, 1994Closed

Complaint · No inspection · Health · 121 employees at the site · Closed Jun 30, 1994

5501 East Oltorf, Austin, TX 78751 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

May 19, 2020, Galveston: Hospitalization · fractures · shoulder(s), including clavicle(s), scapula(e)

Two employees were installing vent pipe and supports on top of a bulk storage tank. There was an explosion in the tank causing the employee working on the tank roof to fall from the tank to the ground. The employee was hospitalized for a fractured shoulder. The second employee was in an aerial lift at the roof line when the tank exploded. The second employee did not fall, but sustained flash…

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.352 · Fire prevention

29 CFR 1926.352(c)

(c) No welding, cutting, or heating shall be done where the application of flammable paints, or the presence of other flammable compounds, or heavy dust concentrations creates a hazard.

29 CFR 1926.352(e)

(e) When the welding, cutting, or heating operation is such that normal fire prevention precautions are not sufficient, additional personnel shall be assigned to guard against fire while the actual welding, cutting, or heating operation is being performed, and for a sufficient period of time after completion of the work to ensure that no possibility of fire exists. Such personnel shall be instructed as to the specific anticipated fire hazards and how the firefighting equipment provided is to be used.

Other petroleum bulk stations and terminals employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.